Herunterladen Inhalt Inhalt Diese Seite drucken

System Exclusive Message - Roland Edirol UR-80 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 83
MIDI implementation
System common message
On the UR-80 you can assign the following system common messages to any
controller and transmit them.
MTC quarter frame
Status
2nd byte
F1H
mmH
mm = Message type/value
Song position pointer
Status
2nd byte
F2H
mmH
mm, ll = Song position:
Song select
Status
2nd byte
F3H
mmH
mm = Song number:
Tune request
Status
F6H
System realtime message
In addition to the Active Sensing messages that are transmitted constantly, the UR-
80 allows you to assign the following system realtime messages (other than Active
Sensing) to any controller and transmit them.
Start
Status
F8H
* Transmitted if the System setting F8 CLOCK is ON.
Start
Status
FAH
Continue
Status
FBH
Stop
Status
FCH
Active sensing
Status
FEH
* Transmitted at intervals of approximately 250 ms.
* Cannot be assigned to a controller.
System reset
Status
FFH
382
3rd byte
llH
00 00H - 7F 7FH (0-16383)
00 00H - 7F 7FH (0-16383)

System exclusive message

The UR-80 is able to transmit the following exclusive messages: exclusive messages
assigned to the controllers, Identity Reply, V-LINK messages, and Bulk Dump.
Universal non-realtime system exclusive
Identity reply
This message will be transmitted when an Identity Request message is received.
Status
Data byte
F0H
7EH,10H,06H,02H,41H,68H,01H,
00H,00H,00H,00H,00H,00H
Byte
Explanation
F0H
Exclusive status
7EH
ID number (Universal non-realtime message)
10H
Device ID (For the UR-80, fixed at 10H)
06H
Sub ID #1 (General Information)
02H
Sub ID #2 (Identity Reply)
41H
ID number (Roland)
68H 01H
Device family code
00H 00H
Device family number code
00H 00H
Software revision level
00H 00H
:
F7H
EOX (End of Exclusive)
V-LINK message
V-LINK ON
Transmitted when entering V-LINK mode.
Status
Data byte
F0H
41H,10H,00H,51H,12H,
10H,00H,00H,01H,0FH,0FH,51H
Byte
Explanation
F0H
Exclusive status
41H
ID number (Roland)
10H
Device ID (For the UR-80, fixed at 10H)
00H 51H
Model ID (V-LINK)
12H
Command ID (DT1)
10H 00H 00H
Address
01H
V-LINK ON
0FH
Clip Control Rx. MIDI Ch. (16ch)
0FH
Color Control Rx. MIDI Ch. (16ch)
51H
Checksum
F7H
EOX (End of Exclusive)
V-LINK OFF
Transmitted when exiting V-LINK mode.
]Status
Data byte
F0H
41H,10H,00H,51H,12H,
10H,00H,00H,00H,70H
Byte
Explanation
F0H
Exclusive status
41H
ID number (Roland)
10H
Device ID (For the UR-80, fixed at 10H)
00H 51H
Model ID (V-LINK)
12H
Command ID (DT1)
10H 00H 00H
Address
00H
V-LINK OFF
51H
Checksum
F7H
EOX (End of Exclusive)
Status
F7H
Status
F7H
Status
F7H

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis