Herunterladen Inhalt Inhalt Diese Seite drucken

Start-Up; Filling Self-Priming Pumps With Water; Checking How Easily The Pump Rotates - BADU 90 Eco Motion Pumpendatenblatt

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 131
Pos : 86 /T echnisc he Dokumentation/Betriebsanl eitung/Inbetri ebnahme/Inbetriebnahme @ 0\mod_1427956937430_370.doc x @ 27298 @ 1 @ 1
6

Start-up

N O T IC E
The pump/unit can be damaged if it runs dry!
Ensure that the pump/unit is always full of water. This also
applies to checking the rotation direction.
Pos : 87 /T echnisc he Dokumentation/Betriebsanl eitung/Inbetri ebnahme/Sel bstansaugende Pumpe mit Wass er füllen @ 0\mod_1427959830385_370.doc x @ 27313 @ 2 @ 1
6.1

Filling self-priming pumps with water

1.
Remove the lid. See chapter 8.1 on page 25.
N O T IC E
High concentrations water treatment chemicals can damage the
pump!
Do not place water treatment products, particularly in tablet
form into the strainer basket.
2.
Fill the pump with clean water up to the inlet connection.
N O T IC E
Tightening the lid too tight when using the opening device will
make it difficult to re-open the lid.
Only apply normal manual force!
3.
Replace and tighten the lid.
Pos : 88 /T echnisc he Dokumentation/Betriebsanl eitung/Inbetri ebnahme/Pumpe auf Leic htgängigkeit prüfen @ 0\mod_1427961952256_370.doc x @ 27328 @ 2 @ 1
6.2

Checking how easily the pump rotates

After longer idle periods, the pump must be checked for how
easily it rotates while it is switched off.
Place a screwdriver in the groove on the end of the motor
shaft on the fan side and turn it.
– or –
If there is not a groove on the end of the motor shaft:
Remove the fan cover and turn the fan wheel manually in the
motor rotation direction.
Pos : 89 /T echnisc he Dokumentation/Allgemei ne Module/#### Sei tenumbruch #### @ 0\mod_1426069111812_0.doc x @ 891 @ @ 1
10|2015
Start-up
EN 21

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis