Carry out programming making sure not to overlap the hours of activation
and/or deactivation on the same day in different programs.
By accessing the submenu: WEEK-END PROGRAM
it is possible to enable/disable and set the week-end
(Saturday - Sunday) chronothermostat functions.
Activate WEEK-END programming only after deactivating the weekly
programming. To avoid unwanted startup and shutdown operations, only
activate one program at a time. Deactivate the daily program if the weekly
program is required; with this setting it is advisable to deactivate the week-
end program.

6.2.2. MENU 02 - USER ADJUSTMENTS

With this menu it is possible to do a number of settings as follows:
Set Clock
Description
Before operating with the boiler, it is necessary to set the current time and date so that
there is a reference for possible chrono programming. The electronic controller has a
lithium battery, model CR2032 3 Volt, giving the internal clock an autonomy of more than
4-5 years; with the boiler off, whenever the clock does not keep the time, or a series of
zeros is displayed at restart, the battery must be replaced by calling an authorised service
centre.
Standby mode
Description
On activating this function, the boiler shuts down automatically after the water temperature
has reached the set value (Tset + ΔT) for a given time. The next automatic relighting will be
possible only when the temperature falls below the SET temperature by a few degrees and
precisely (Tset - ΔT) where ΔT default = 2°C. Manual commands from the control panel
have priority over programming. With the selection OFF the boiler does not activate the
STANDBY mode and functions normally activating the MODULATION function when the
temperature exceeds the SET value.
Initial load
Description
Setting this function allows activation of gearmotor operation, with the boiler off or cold, for
pellet preloading of 90 sec. It starts with button P1 and stops with button P4.
Pellet type
Description
With the function on, press the buttons P1 or P2 to increase or reduce pellet loading to
optimise consumption and combustion, depending on the type of pellets used.