▪ have a free section of at least 6 cm
for the opening must not be less than 100 cm
▪ the opening must be at the bottom of an external wall, preferably opposite the one for the
flue gas exhaust.
Items and parts that are sensitive to heat or flammable upon contact with the
product shall not be stored; these items shall nevertheless be kept at a minimum
frontal distance of 100 cm from the outermost point of the product.

5.4 INSTALLATION

Installation operations must be carried out by a technician who is qualified
and/or authorised by the Manufacturer in compliance with the regulations
in force in the country of installation (Italy UNI10683), which must provide
verbal instructions to the user before using the unit.
Permissible environmental conditions
Ventilated environment.
Minimum environmental temperature = no less than 0°C
Minimum frontal distance for protecting flammable items = 1 m
Supplementary
hopper
(optional)
Flue sampling point
for emissions check
64
NATURFIRE EVO 27 - 34
for every 1 kW (859.64 kcal/h). The minimum section
2
.
2
MINIMUM MAINTENANCE AND SAFETY DISTANCES
A = 500 mm
B = 500 mm
C = 500 mm
D = 1000 mm
Boiler
Flue connection
cod.48427M013_11/19
L = 1450 mm
P = 700 mm
Antiwind cap
Flue
Flue
inspection
chamber
Wall socket
min. 100 cm
T union with
inspection cap
2
EN