End limits adjustment
4
- If the installation includes several motors, only one motor is to be powered during this program-
ming procedure. It will eliminate interferences with the other motor during the procedure.
4.1 Learning mode
a- Switch ON the motor.
b- Simultaneously press the UP and DOWN keys of a Hz transmitter. The motor will
run for half a second in one direction and then in the other. The transmitter
now controls the EHz motor in unstable mode, Go to stage 4.2.
4.2- Checking the rotation direction
Press the UP key of the transmitter:
a- If the motorized tube runs in the UP direction ,
move to next stage (4.3).
b- If the motorized tube runs in the DOWN direction,
reverse the rotation direction by pressing the STOP
key for at least 3 seconds. The motor will confirm
the reversal of the rotation direction by running 1/2
second in both directions. Go to stage 4.3.
4.3- Adjustement of the end-limits : memorizing the end points
The end limits of the T5EHz are adjusted in 4 different ways depending on the following conditions :
- Bottom slat stop or not, stiff or flexible* link between the rolling shaft and the shutter.
A
*V.A.R
V.A.S
A
1
B
1
1- Position the motor on the UP end limit by using the keys UP or DOWN.
2- To memorize the UP end limit position, press simultaneoulsy the keys STOP and DOWN. The motor will run
automatically in the DOWN direction.
3- Press the STOP key to immobilize the motor.
4- Press 2 seconds the STOP key to validate the setting. The motor will run for half a second in one direction,
then in the other direction. Go to stage §5.
C
1
1- Position the motor on the DOWN end limit by using the keys UP or DOWN.
2- To memorize the DOWN end limit position, press simultaneoulsy the keys STOP and UP. The motor will run
automatically in the UP direction.
3- Press the STOP key to immobilize the motor.
4- Press 2 seconds the STOP key to validate the setting. The motor will run for half a second in one direction,
then in the other direction. Go to stage §5.
B
*V.A.R
V.A.S
2
2s
2
2
>>
a
>>
b
>>
C
1- Simultaneously press the UP and DOWN keys of a Hz transmitter. The
motor will run for 1/2 second in one direction and then in the other.
2- Press the "stop" key for 2 s. The motor will run for 1/2 second in one
direction and then in the other. The operation is completed. Go to
stage §5.
3
3
1
ON
OK
>> 4.3
>>
3s
D
4
4
2
>>
>> OK >> 4.3
2s
2s