Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Assembly
1.
Flush through the supply pipes.
2.
Place the mixer including the sealing washer in
position on the basin.
3.
Slip the fixation piece including the washer over
the threaded pins and tighten the nuts.
4.
Connect the supply pipes to the isolation
valves;cold right - hot left.
5.
Connect the pull rod to the pop-up waste.
The hot and cold water supply's should be of equal
pressures.

Operation

The mixer is activated by lifting the lever handle.
Move to the left = hot water,
move to the right = cold water.

Technical Data

Rate of flow:
Operating pressure:
Recommended operating pressure 0.1 - 0.5 MPa
Test pressure:
(1 MPa = 10 bars = 147 PSI)
Hot water temperature:
Recommended hot water temp.: 65° C
Test certificate 31701000:
Hansgrohe single lever mixers can be used together
with hydraulically and thermically controlled con-
tinuous flow heaters if the flow pressure is at least
0.15 MPa.
If the continuous water heater causes any problems or
there is not enough flow of water, the waterdimmer
(5a) located behind the aerator must be removed.
To adjust the hot water limiter on single lever mixers,
please see page 23.
No adjustment is necessary when using a continu-
ous flow water heater.
8
English
7.2 l/min 0.3 MPa
max. 1 MPa
1.6 MPa
max. 80° C
WRAS
®
Spare parts (see page 4)
1�
handle
1.1 screw cover
2�
flange
3�
nut
4�
cartridge cpl.
5�
aerator cpl.
6�
pop up rod
7�
fixing set
8�
connection hose 3/8"
connection hose
9�
10�
seal
11�
chain for plug
12�
adapter for cartridge
13�
screw
31793000
96338000
97406000
97209000
92730000
13912000
96657000
96016000
97206000
96321000
97608000
97109000
98750000
97736000