11. Troubleshooting

Error code

In case of heat pump malfunction, an error code will show on the display.
Select the error code menu and press the settings button to enter and see
the error description. See an example on the right.
Malfunctions
Inlet water temperature sensor
fault
Outlet water temperature sensor
fault
Heating condenser sensor fault
Gas return sensor fault
Ambient temperature sensor fault
Condenser gas outlet sensor fault
Antifreeze protection in the winter
Low ambient temperature protec-
tion
Cooling condenser temperature
too high protection
T2 water temp. Protection in the
cooling mode is too low
High pressure
142
Error
Reason
code
The sensor is open or has a
PP01
short circuit
The sensor is open or has a
PP02
short circuit
The sensor is open or has a
PP03
short circuit
The sensor is open or has a
PP04
short circuit
The sensor is open or has a
PP05
short circuit
The sensor is open or has a
PP06
short circuit
The ambient temperature
PP07
or water inlet temperature is
too low
The ambient temperature
PP08
or water inlet temperature is
too low
The cooling condenser tem-
PP10
perature is too high
PP11
1. Too much refrigerant
EE01
2. Insufficient airflow
MV-1401-1402-1403-01-2020 . © All rights reserved Swim & Fun Scandinavia ApS
Solution
Check or change the sensor.
Please create a complaint, your heat
pump needs to be serviced -
https://swim-fun.dk/en/support
Wait for the temperature to be within
the heat pump tolerance
Check or change the sensor.
Please create a complaint, your heat
pump needs to be serviced -
https://swim-fun.dk/en/support
Stop the heat pump and wait until the
temperature of the cooling condens-
er drops.
1. Water pump
fault
2. Water pipe
blocked
Please create a
3. Flow switch
complaint, your
blocked
heat pump needs
1. Discharge
to be serviced -
excess refrig-
https://swim-fun.
erant from the
dk/en/support
heat pump's gas
system
2. Clean the air
exchanger
UK

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

14021403

Inhaltsverzeichnis