Parameter checking
Select the parameter menu A and press the settings button B to enter the menu. Press C or D but-
ton to check codes between d0 and d11
Usage parameters d0 to d11
Code
Condition
d0
IPM temperature
d1
Water temperature (inlet)
d2
Water temperature (outlet)
d3
Ambient temperature
d4
Frequency limitation code
d5
Pipe temperature
d6
Exhaust gas temperature
d7
Step of EEV
d8
Compressor working frequency
d9
Compressor current
d10
Fan Speed
d11
Error code for the last time
Remark: d4 Frequency limitation code, 0: No frequency limit; 1: Coil pipe temperature limit; 2: Overheating or overcooling
frequency limit; 4: Drive Current frequency limit; 8: Drive voltage frequency limit; 16:Drive high temperature frequency limit
MV-1401-1402-1403-01-2020 . © All rights reserved Swim & Fun Scandinavia ApS
T1≥Tset
Tset >T1≥Tset-1
"Smart mode"
Tset-1 >T1≥Tset-2 27°C >T1 ≥ 26°C Frequency: F2 -F3-F4,...,-F9
<Tset-2
≥Tset
"Silent mode"
Tset>T1≥Tset-1
T1<Tset-1
"Powerful mode"
T1<Tset-1
A
T1 ≥ 28°C
28°C > T1 ≥ 27°C Silent mode - frequency F2
<26°C
≥28°C
28°C > T1 ≥ 27°C Smart mode - frequency F5
T1 < 27°C
T1 < 27°C
B
C
D
Scope
0-120 °C
-9 °C ~ 99 °C
-9 °C ~ 99 °C
-30 °C ~ 70°C
0, 1, 2, 4, 8, 16
-30 °C ~ 70 °C
0 °C ~ C5 °C (125 °C)
0~99
0~99Hz
0~30A
0-1200 (rpm)
All error codes
Standby
Powerful mode - frequency F9
Silent mode - frequency F2/F1
Powerful mode - frequency F10/F9
Standby
Remark
Real testing value
Real testing value
Real testing value
Flash if Real test value <-9
Real testing value
Flash if Real test value <-9
Real testing value
N*5
Real testing value
Real testing value
Real testing value