Herunterladen Inhalt Inhalt Diese Seite drucken

Swim & Fun 1401 Handbuch Seite 136

Vorschau ausblenden Andere Handbücher für 1401:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 153
How the Heating Mode works
Working
NO
status
1
2
3
4
5
Start-up of
heat pump
6
7
8
9
10
11
Restart to
12
heat water
13
in standby
14
status
15
16
17
How the Cooling Mode works
Working
NO
status
1
2
3
4
Start-up of
5
heat pump
6
7
8
9
136
T1=Water inlet temperature /Tset= set temperature=28°C
Water inlet
Working mode
Temperature
T1< Tset-1
Tset-1≤T1 <Tset
"Smart mode"
Tset≤T1 <Tset+ 1 28°C ≤ T1 <29°C Silent mode - frequency F2
T1≥Tset
T1<Tset
Tset≤T1 < Tset+1
"Silent mode"
T1≥Tset+1
T1<Tset+1
"Powerful mode"
T1≥Tset+1
T1≥Tset
Tset >T1≥Tset-1
"Smart mode"
Tset-1 >T1≥Tset-2 27°C >T1 ≥ 26°C Frequency: F2 -F3-F4,...,-F9
<Tset-2
≥Tset
"Silent mode"
Tset>T1≥Tset-1
T1<Tset-1
"Powerful mode" T1<Tset-1
T1=Water inlet temperature /Tset= set temperature=28°C
Water inlet
Working mode
Temperature
T1< Tset-1
"Smart mode"
Tset-1≤T1 <Tset
Tset≤T1 <Tset+ 1 28°C ≤ T1 <29°C Frequency: F9 -F8-F7,...,- F2
T1≥Tset
T1<Tset
Tset≤T1 < Tset+1
"Silent mode"
T1≥Tset+1
T1<Tset+1
"Powerful mode"
T1≥Tset+1
Example
T1< 27°C
27°C ≤ T1 <28°C Frequency: F9 -F8-F7,...,-F2
T1 ≥ 29°C
T1 < 28°C
28°C ≤ T1 < 29°C Silent mode - frequency F2/F1.
T1 ≥ 29°C
T1 < 29°C
T1 ≥ 29°C
T1 ≥ 28°C
28°C > T1 ≥ 27°C Silent mode - frequency F2
<26°C
≥28°C
28°C > T1 ≥ 27°C Silent mode - frequency F2/F1
T1 < 27°C
T1 < 27°C
Example
T1< 27°C
27°C ≤ T1 <28°C Silent mode - frequency F2
T1 ≥ 29°C
T1 < 28°C
28°C ≤ T1 < 29°C Silent mode - frequency F2/F1.
T1 ≥ 29°C
T1 < 29°C
T1 ≥ 29°C
MV-1401-1402-1403-01-2020 . © All rights reserved Swim & Fun Scandinavia ApS
Heat pump working level
Powerful mode - frequency F9
Heat pump will be in Standby, until the
water temperature drops below 28°C.
Smart mode - frequency F5.
Heat pump will be in Standby, until the
water temperature drops below 28°C.
Powerful mode - frequency F10/F9
Heat pump will be in Standby, until the
water temperature drops below 28°C.
Standby
Powerful mode - frequency F9
Standby
Smart mode - frequency F5
Powerful mode - frequency F10/F9
Heat pump working level
Standby
Powerful mode - F9
Standby
Smart mode -frequency F5
Powerful mode - frequency F10/F9
Standby
UK

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

14021403

Inhaltsverzeichnis