Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 113
UK
This warranty is in lieu of all other warranties, expressed or implied, including but not limited to any
implied warranty of fitness for a particular purpose and saleability. We expressly disclaim all liability
for consequential damage, accidental damage, indirect loss or loss related to a breach of the ex-
pressed or implied warranty.
This warranty gives you specific legal rights, which may vary by country.
Complaints
In the event of a complaint, the dealer must be contacted and a valid purchase receipt presented.
IMPORTANT!
If you need technical help – contact Swim & Fun Scandinavia ApS
on the service hotline:
DK-telephone +45 7022 6856 Monday – Friday from 09.00 – 15.00.

11. Troubleshooting

Malfunctions
Inlet water temperature sensor
fault
Outlet water temperature sensor
fault
Heating condenser sensor fault
Gas return sensor fault
Ambient temperature sensor fault
Condenser gas outlet sensor fault
Antifreeze protection in the winter
Low ambient temperature protec-
tion
Cooling condenser temperature
too high protection
T2 water temp. Protection in the
cooling mode is too low
MV-1225-1225-1298-11-2018 . © All rights reserved Swim & Fun Scandinavia ApS
Error
Reason
code
The sensor is open or has a
PP01
short circuit
The sensor is open or has a
PP02
short circuit
The sensor is open or has a
PP03
short circuit
The sensor is open or has a
PP04
short circuit
The sensor is open or has a
PP05
short circuit
The sensor is open or has a
PP06
short circuit
The ambient temperature
PP07
or water inlet temperature is
too low
The ambient temperature
PP08
or water inlet temperature is
too low
The cooling condenser tem-
PP10
perature is too high
PP11
Solution
Check or change the sensor
Check or change the sensor
Check or change the sensor
Check or change the sensor
Check or change the sensor
Check or change the sensor
Stop the heat pump and wait until the
temperature of the cooling condens-
er drops.
1. Water pump fault
2. Water pipe blocked
3. Flow switch blocked