Anemometer
Test the operation of the anemometer by
spinning the cups. Check that the speed
indicated on the display changes in relation
to the speed of the cups.
Rain sensor
Rock the outdoor unit from side to side
and listen for clicking sounds. Each click
represents 0.3 mm rainfall. Check that
the reading indicated on the display
changes as the outdoor unit is rocked.
Thermometer/Hygrometer
Place the outdoor unit close to the indoor
unit and leave it for about 30 minutes
for it to acclimatise to the new ambient
temperature. Compare the temperature
and humidity readings from both units.
The temperature readings should not
differ more than 1 °C (accuracy ±0.5 °C)
and the humidity readings should not differ
by more than 6 % (accuracy ±3 %).
If the difference in the readings is outside
these limits, the accuracy can be adjusted
by calibrating the indoor unit. Refer to
the Calibration section.
Test the operation of the wind direction
sensor by moving the weather vane.
Check that the direction indicated on
the display changes as the weather
vane is turned.