Connect cables, close cable cover
7.1
Connection for DC Power Source
NOTICE: Physical damage
Only trained service personnel are authorized to install and remove the 9 to 60 VDC power
supply, and make the connections to and disconnections from the 9 to 60 VDC power source.
The customer is responsible for ensuring that only trained service personnel install or remove
the 9 - 60 V power cable
Fuse - Non-operator access/soldered-in fuses, for 6.3 A / 250 V input DC board only:
Replacement of fuses replaceable only by service personnel.\
Fuse - Non-operator access/soldered-in fuses, for 6.3 A / 250 V input DC board only:
Replacement of fuses replaceable only by service personnel.
7.1.1 Connect the Power supply
NOTICE: Physical damage
 The DC supply source for the equipment power supplied shall be an UL listed power source
and suitable for specification, rated 60 VDC, 5 A minimum provided by the manufacturer.
Please use the jacketed power cable with 60 V, 18 AWG or 6 Amp. to connect between the
equipment and the DC power source.
 This product is intended to be supplied by a listed DC power source, rate 9 to 60 VDC,
5 A minimum and Tma 45 degree C, if need further assistance, please contact Advantech-
DLoG for further information.
1.
Turn off DC supply source and equipment that is to be connected to this product.
2.
Ensure DC power source connected earthed cable.
3.
Connect the earthed cable which is of AWG 20 min. green-and-yellow wire of earth of
building to the protective earthed terminal of the equipment
4.
Connect signal cables to the product
5.
Connect power cord to the product
6.
Ensure correct polarity of 9 - 60 VDC connections
7.
Turn ON the power source
8 / 16
Quick Start Guide DLT-V4108, V01