These instructions apply to model FAAC D600.
The D600 automated systems make it possible to automate
balanced sectional doors of single garages for residential
use.
They consist of an electro-mechanical operator, electronic
control unit and courtesy light built into a single unit. This unit is
fitted to the ceiling and opens the door by means of a transmission
chain or belt.
The system is non-reversing and, therefore, the door locks
mechanically when the motor is not operating and, consequently,
no lock is necessary; two manual releases, one on the inside
and one on the outside (optional) make it possible to move the
door in case of a power cut or fault.
The operator is supplied with an electronic device that detects
the presence of an obstacle that would hinder door movement
- the device prevents crushing or lifting.
This instruction refers to the operator with chain drive, but the
same procedures, regulations and application limits apply also
to the belt driven operator.
The D600 automated systems were designed and built for
indoor use and to control vehicle access. Do not use them for
any other purpose.

1 DIMENSIONS

200
Fig. 1
AUTOMATED SYSTEM D600
Dimensions in mm.
145
4

2 TECHNICAL SPECIFICATIONS

Model
Power supply (V ~ / 50 Hz.)
Electric motor (Vdc)
Maximum absorbed power (W)
Thrust force (N)
Type of use
Maximum dimensions from ceiling (mm)
Courtesy light (V ~/W)
Courtesy light timer (sec)
Standard speed with no-load carriage (m/min)
Slow speed with no-load carriage (m/min)
Carriage deceleration speed (m/min)
Noise at standard speed (dB(A))
Travel length at deceleration
Intrinsic safety device
Maximum sectional door width (mm)
Maximum sectional door height (mm)
Sliding guide useful travel (mm)
Protection class
Operating ambient temperature (°C)
The level of noise emission of operator D600, referred
to the work station, is 52 dB(A).

3 ANCILLARY ELECTRICAL EQUIPMENT

Prepare the electric system in keeping with the instructions in
the chapter entitled "Warnings for the installer".
When you have finished installing, check if any external pipes
or cables can come into contact with moving parts.
Install the fixed control points at a minimum height of 150 cm,
clear of the door movement area, but in a position enabling
visual control of that area.
Cable 2 x 0.5 mm
(TX photocell)
2
Cable 4 x 0.5 mm
(RX photocell)
2
Power pipe (230V)
Low voltage pipe
Cable 2 x 1.5 mm
(power)
2
D600
230
24
220
600
continuous
35 (Fig. 4)
230 / 40 max.
120
6,6
3,8
1,3
52
varies according to set-up
Category 2
5000
(see useful travel)
1900 - 2500 - 3100
for indoor use only (IP20)
-20 / +55
Fig. 2