3.
Press the tabulator key:
Next Timer
Level
A B C
hrs
Back
F1
F2
Service menu
The screen shows that the next service plans to be carried out
are plans A, B and C and that these plans are to be carried out
each 4000 running hours.
~
4.
Press the
key to find which service plans were carried out
previously:
Previous Timer
Level
A B
hrs
F1
F2
Service menu
The screen shows that service plans A and B were carried out at
2008 running hours.
5.
Stop the dryer, switch off the voltage and carry out the service
operations related to plans A, B and C.
6.
Switch on the voltage and scroll to the service screen. Press the
"Rset" button (F3) to reset the timer. Confirm the question for
resetting.
Notes
The "Rset" button only appears when the next Timer level is
almost reached (from 400 running hours before elapsing of the
service plan interval).
|
After pressing the
key, the Life time hours are shown (i.e. the
number of hours elapsed since initial programming ex-factory).
This counter is not taken into account.
2904 0177 04
~
4000
Rset
F3
|
2008
F3

Saved data menu

Function
To call up some dryer data saved by the regulator. These data are:
Last emergency stop data
Procedure
1.
Starting from the Main screen:
– press the key "Menu" (F1)
~
– press the
key until the option "Saved data" is followed by a
horizontal arrow
– press the tabulator key to activate the menu
2.
The list of last emergency stop cases is shown.
3.
Scroll through the items to select the desired emergency stop
item.
4.
Press the tabulator key to find the date, time and other data
reflecting the status of the compressor at the last shut-down
occurred.

Protections

Protection
Dryer inlet pressure for 11 bar units
Dryer inlet pressure for 16 bar units
Dryer inlet temperature
Dryer regenerating pressure
Pressure dewpoint
I
NSTRUCTION MANUAL
Minimum
Nominal
Maximum
3.5 bar
7 bar
11 bar
10.5 bar
12.5 bar
16 bar
1 °C
35 °C
45 °C
0 bar
0,7 bar
1 bar
-45 °C
-40 °C
-20 °C
11