Herunterladen Inhalt Inhalt Diese Seite drucken

Waeco CoolAir CA-1000-AC Einbau- Und Bedienungsanleitungen Seite 39

Dachklimaanlage
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
_CA-1000.book Seite 39 Freitag, 28. Juli 2006 10:35 10
CoolAir
The roof of the vehicle can be reinforced (e.g. with a wooden frame) if the
load-bearing capacity of the roof is insufficient.
➤ Position the roof air conditioner over the installation opening.
5.2.6 Fastening the system
– see fig. 10 on page 6 –
➤ Mount the fastening frame with the self-locking nuts (4 x M8) and
Tighten to the specified torque.
➤ Tighten the screws using a torque wrench and a fastening torque of
5.2.7 Installing the air outlet unit
When attaching the suction head of the air outlet unit, make sure that the
screws are tightened with due care, to avoid overwinding. Jerking and
dragging on the suction head must be avoided, as it could come loose
from the intake hose.
➤ Insert both plugs of the connection line (ribbon cable) between the
➤ Connect the suction head to the air outlet unit. For this use the 6
➤ Attach the air outlet unit to the fastening frame with the 4 self-tapping
Observe the direction of travel.
washers (4 x M8) provided.
(3 Nm) 0.3 kg/m.
system and the air outlet unit into the socket on the control board (see
arrow, see fig. 11 on page 6).
countersunk screws provided (3.5 x 13) (see fig. 12 on page 6).
screws (4.8 x 25) (see fig. 13 on page 7). At this point make sure that
the air outlet unit is fastened securely to the roof.
Installation
39

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading