• Employ this product only for the use for which it was expressly made. Any
other use is dangerous. CAME S.p.A. is not liable for any damage caused by
improper, wrongful and unreasonable use • Keep these warnings together
with the installation and operation manuals that come with the operator.
Before installing
(checking what's there: if your evaluation is negative, do not proceed before
having complied with all safety requirements)
• Check that the automated parts are in good mechanical order, that the
operator is level and aligned, and that it opens and closes properly. Make
sure you have suitable mechanical stops • If the operator is to be installed at
a height of over 2.5 m from the ground or other access level, make sure you
have any necessary protections and/or warnings in place • If any pedestrian
openings are fi tted into the operator, there must also be a a system to block
their opening while they are moving • Make sure that the opening automated
door or gate cannot entrap people against the fi xed parts of the operator •
Do not install the operator upside down or onto elements that could yield and
bend. If necessary, add suitable reinforcements to the anchoring points • Do
not install door or gate leaves on tilted surfaces • Make sure any sprinkler
systems cannot wet the operator from the ground up • Make sure the tempe-
rature range shown on the product literature is suitable to the climate where
it will be installed • Follow all instructions as improper installation may result
in serious bodily injury • It is important to follow these instructions for the
safety of people. Keep these instructions.
Installing
• Suitably section off and demarcate the entire installation site to prevent
unauthorized persons from entering the area, especially minors and children
• Be careful when handling operators that weigh over 20 kg. If need be, use
proper safety hoisting equipment • All opening commands (that is, buttons,
key switches, magnetic readers, and so on) must be installed at least 1.85
m from the perimeter of the gate's working area, or where they cannot be
reached from outside the gate. Also, any direct commands (buttons, touch
panels, and so on) must be installed at least 1.5 m from the ground and must
not be reachable by unauthorized persons • All maintained action comman-
ds, must be fi tted in places from which the moving gate leaves and transit
and driving areas are visible • Apply, if missing, a permanent sign showing
the position of the release device • Before delivering to the users, make sure
the system is EN 12453 standard compliant (regarding impact forces), and
also make sure the system has been properly adjusted and that any safety,
protection and manual release devices are working properly • Apply Warning
Signs (such as the gate's plate) where necessary and in a visible place
Special user-instructions and recommendations
• Keep gate operation areas clean and free of any obstructions. Make sure
that the photocells are free of any overgrown vegetation and that the opera-
tor's area of operation is free of any obstructions • Do not allow children to
play with fi xed commands, or to loiter in the gate's maneuvering area. Keep
any remote control transmitters or any other command device away from
children, to prevent the operator from being accidentally activated. • The
apparatus may be used by children of eight years and above and by physi-
cally, mentally and sensorially challenged people, or even ones without any
experience, provided this happens under close supervision or once they have
been properly instructed to use the apparatus safely and about the potential
hazards involved. Children must not play with the apparatus. Cleaning and
maintenance by users must not be done by children, unless properly super-
vised • Frequently check the system for any malfunctions or signs of wear
and tear or damage to the moving structures, to the component parts, all
anchoring points, including cables and any accessible connections. Keep any
hinges, moving joints and slide rails properly lubricated • Perform functional
checks on the photocells and sensitive safety edges, every six months. To
check whether the photocells are working, wave an object in front of them
while the gate is closing; if the operator inverts its direction of travel or sud-
denly stops, the photocells are working properly. This is the only maintenance
operation to do with the power on. Constantly clean the photocells' glass co-
important safety instructions for people:

READ CAREFULLY!

Premise
WARNING!
vers using a slightly water-moistened cloth; do not use any solvents or other
chemical products that may ruin the devices • If repairs or modifi cations are
required to the system, release the operator and do not use it until safety
conditions have been restored • Cut off the power supply before releasing
the operator for manual openings and before any other operation, to prevent
potentially hazardous situations. Read the instructions • If the power supply
cable is damaged, it must be replaced by the manufacturer or authorized
technical assistance service, or in any case, by similarly qualifi ed persons,
to prevent any risk • It is FORBIDDEN for users to perform any OPERATIONS
THAT ARE NOT EXPRESSLY REQUIRED OF THEM AND WHICH ARE NOT LISTED
in the manuals. For any repairs, modifi cations and adjustments and for ex-
traordinary maintenance, CALL TECHNICAL ASSISTANCE • Log the job and
checks into the periodic maintenance log.
Additional special recommendations for everyone
• Keep away from hinges and mechanical moving parts • Do not enter the
operator's area of operation when it is moving • Do not counter the opera-
tor's movement as this could result in dangerous situations • Always pay
special attention to any dangerous points, which have to be labeled with
specifi c pictograms and/or black and yellow stripes • While using a selector
switch or a command in maintained actions, keep checking that there are no
persons within the operating range of any moving parts, until the command
is released • The gate may move at any time and without warning • Always
cut off the power supply before performing any maintenance or cleaning.
Danger of foot crushing
Danger of hand crushing
Danger! High voltage.
No transiting while maneuvering

Werbung