INSTALLATION

UNPACKING

The Quick-Therm Salamander is shipped with most
components installed and ready for operation. The following
installation instructions must be preformed before plugging in
and operating the Salamander.
1. Remove unit from box.
2. Remove information packet.
3. Remove tape or protective film from all surfaces of unit.
4. Remove locking screws used to secure upper housing
during shipping and discard. (See 3 )

LOCATION

The Salamander can be wall mounted to a cement or brick wall
or stand alone on a countertop. Position of the unit must meet
the specified requirements listed in the following procedures
and safety precautions.
WARNING
For safe and proper operation, the unit must be located a
reasonable distance from combustible walls and
materials.
If
safe
distances
discoloration or combustion could occur.
WARNING
The unit is not waterproof. DO NOT submerge in water. To
prevent any injury or damage, do not operate if unit has
been submerged in water.
WARNING
To avoid the risk of fire or unit malfunction do not obstruct
the air intake openings or the air exhaust openings located
on the outer housing of the unit.
WARNING
To avoid any injury or damage to the unit, when wall
mounting only use the special bracket provided with the
appropriate hardware suitable for a cement or brick and
unit weight.
WARNING
To reduce the risk of fire, the QTS-1 appliance is to be
mounted on a countertop of noncombustible material and
surface finish with no combustible material against the
underside, or on noncombustible slabs or arches, and
have no combustible material against the underside. Such
construction shall in all cases extend not less than
305 mm (12") beyond the equipment on all sides.
CAUTION
To avoid any injury or damage, locate the unit at the
proper counter height, in an area that is convenient for
use. The location should be level to prevent the unit or its
contents from accidentally falling, and strong enough to
support the weight of the unit and food.
NOTE: A qualified person must check possible placements of
the Salamander to ensure that the proper electrical supply line
is available.
Form No. QTSCEM-0907
are
not
maintained,
6
Countertop Location
The ideal placement for the Salamander is directly underneath
an exhaust hood to guarantee total suction of steam produced
when cooking.
1. Place the unit in a suitable location based on a minimum of
51 mm (2") distance from any wall. (See 4 )
2. Adjust leveling feet until Salamander is level front to back
and side to side.
3. Connect unit to the proper electrical supply line.

ELECTRICAL CONNECTIONS

WARNING
To prevent injury or damage to the unit, QTS-1 model must
be installed by a qualified electrician.
WARNING
To assure safe and proper operation, when connecting unit
direct to main terminal block, a 4-pole switch must be
installed between the unit and the main supply. The switch
must be rated properly and have contacts with a minimum
opening distance of 3 mm.
CAUTION
To assure safe and proper operation the supply voltage
must not differ from the rated voltage value by ±10% and
must be connected to a system and uniform potential.
NOTICE
To avoid any damage to the unit, make sure the electrical
supply matches the voltage and frequency rating on the
specification plate.
NOTE: A qualified person must check possible placements of
the Salamander to ensure that the proper electrical supply line
is available.