7. Initial operation

Multiple Power System MPS®:
The rated capacity (max. power con­
sumption) is 27 kW / 400 V and can be
changed internally to 24 kW, 21 kW or
18 kW.
Before making the electrical connection, fill the mains and the appliance with water
by carefully opening and closing the hot water tap in order to vent completely.
To ensure a maximum flow, remove any existing aerator from the faucet. Flush the
warm and cold water pipes each at least for one minute.
After every draining (e.g. after work on the plumbing system or following repairs to
the appliance), the heater must be re-vented in this way before starting it up again.
If the water heater cannot be put into operation, the temperature cut­out or the pres­
sure cut­out may have tripped during transport. If necessary, reset the cut­out.

Selection of power rating

Only by authorised specialist, otherwise lapse of guarantee!
Upon first connection of the appliance to the supply voltage, select the maximum
power rating. Only after having set the power rating, the heater provides its standard
operation mode.
The maximum allowable power rating at installation site depends on the local situa­
tion. It is imperative to observe all data shown in the table "Technical specifications",
in particular the required cable size and fuse protection for the electrical connection.
Moreover, the electrical installation must comply with the statutory regulations of the
respective country and those of the local electricity supply company (Germany: DIN
VDE 0100).
1. Switch on the power supply to the appliance.
2. When switching on the supply voltage for the first time, the touch screen shows
the menu to select the language after about 40 seconds. Choose your language,
after that the selection of power rating appears. If not, please follow the note

"Reinstallation".

3. Select the maximum allowable power rating depending on the local situation via
touch (18, 21, 24 or 27 kW).
4. Press "OK" to confirm the setting.
5. Mark the set power rating on the rating plate.
®
6. After having set the maximum allowable power rating, the heating element will be
activated after approx. 10 – 30 sec of continuous water flow.
7. Open the hot water tap. Check the function of the appliance.
8. Remove the battery case cover of the remote control and insert batteries (2 × AAA
Alkaline). Mind the polarity of the batteries. Insertion should take place when the
power supply of the water heater is turned on and the remote control is near the
appliance. The display indicates all symbols for about 4 seconds after inserting the
batteries, after that the remote control is connected to the instantaneous water
heater.
9. Explain the user how the instan ta neous water heater works and hand over the oper­
ating instructions to the user.
10. Fill in the guarantee registration card and send it to the CLAGE After­Sales Service
or use the online regis tration on our website (see also page 2).
Reinstallation
In case the appliance will be commis sioned again under different installation conditions
than during its initial ope ration, it may be necessary to adapt the maximum power rat­
ing.
A temporary short­circuit of the two pins on the right, e.g. with a screwdriver acc.
to EN 60900 (see figure), will reset all heater parameters to works setting and lock
the heating. The touch screen shows the menu to select the language. Choose your
language, after that the selection of power rating appears. This condition will maintain
when activating and deactivating the supply voltage.