Self-regulation of the functioning parameters (AUTO)
The first and most important function to program is the self-regulation of the parameters, which allows the control unit to automatically set the end run points, the torque applied
to the leaf and the torque in the slowing phase*.
During the autoset operations, the control unit automatically performs several opening and closure manoeuvres.
Before proceeding, check that no person, animal or obstacle is or can be in the door manoeuvre area.
All the accessories provided for the system should be already connected to the control unit. If further accessories should be added,
self-adjustment must be repeated.
Proceed as follows:
1- Apply mains power supply to the automation via the pre-wired socket, using an extension if necessary.
2- Release the leave, take it manually to about half of the run and block it again.
3- Start the autoset phase as described below. As soon as the first manoeuvre starts, carefully check that the leaf moves in the closure direction. If this is not the case, press " " and
"PGM" at the same time to interrupt the autoset. The display shows the ERR message. Use the movement direction reverse button (MINV menu) and change the direction of movement.
1
Press the button [PGM] to access programming.
2
The display shows AUTO, select Auto by pressing the [PGM] button.
AUTO starts to flash slowly. Press and hold the [PGM] key, after 5 seconds AUTO starts to flash quickly, release the key only when the
3
display shows the PRG message.
The self-regulation phase starts, the display shows PRG. The control unit commands different opening and closing manoeuvres at
4
various speeds.
At the end of the manoeuvre the display shows "OK"
The control unit goes back to the AUTO menu. To exit programming, press the [PGM] and [ ] buttons at the same time or, alternatively,
5
remove the power supply or wait 60 seconds.
* The slowing phase must be activated via the TSM parameter. The control unit is supplied with the parameter set at 0 (Off); the AUTO function does not activate slowing but is
limited to defining a suitable torque value.
The intervention of the photocells or any other command from the transmitter or key selector, interrupts the autoset phase, displaying the message ERR1/2/3. The
procedure must therefore be repeated.
Every self-regulation procedure overwrites the previous one. Perform an autostop procedure after every maintenance intervention or modification of the door.
Regulation of the automatic closure time (TCA)
The automatic closure function allows to set a time which, on expiry, if the leaf is in the open position the control unit autonomously commands a closure manoeuvre.
With this function active, if you forget to give the closure command or in the case of simultaneous commands, the control unit closes the leaf after the set time.
The factory setting envisions 30 seconds before automatic closure.
Press the [PGM] button to access programming or if the control unit is already in the programming menu, press [ ] until the TCA
1
function is displayed.
Press the [PGM] button to enter the TCA parameter regulation.
The display shows the current value of the TCA parameter.
Use the [ ] key to select one of these values:
0
The TCA function is deactivated.
2
1
The pause time is set at 10 seconds (default setting
2
The pause time is set at 30 seconds)
3
The pause time is set at 60 seconds
4
The pause time is set at 90 seconds
3
Confirm the desired value using the [PGM] key, the display shows PRG.
The control unit goes back to the TCA menu. To exit programming, press the [PGM] and [ ] buttons at the same time or, alternatively,
4
remove the power supply or wait 60 seconds.
Regulation of the motor thrust (PMOT)
The force applied is normally set automatically by the control unit during the self-regulation phase (AUTO).
This menu can be used to modify that set by the control unit, to make up for a friction point for example.
Press the [PGM] button to access programming or if the control unit is already in the programming menu, press [ ] until the PMOT
1
function is displayed.
Press the [PGM] button to enter the PMOT regulation.
The display shows the current value of the PMOT parameter.
Use the [ ] key to select one of these values:
2
1
low motors torque
2
medium/low motors torque
3
medium/high motors torque
4
high motors torque (default setting)
3
Confirm the desired value using the [PGM] key, the display shows PRG.
The control unit goes back to the PMOT menu. To exit programming, press the [PGM] and [ ] buttons at the same time or, alternatively,
4
remove the power supply or wait 60 seconds.
EN
PGM
AUTO
PRG
PGM+
TCA
0000
0004
PRG
PGM+
pmot
PMOT
PMOTPMOT
0001
0004
PRG
PGM+