Ref.
Control/Indicator
Name
1
2
TSP FILAMENT
1 , 2, 3
3
SEL
4
ON/OFF
5
SUBLIMATION
6
MINI TIBALL
7
SET
8
MODE
9
! / "
[
]
Sublimation Controller Rear Panel
The following figure shows the controls and the connections of
the Sublimation Controller rear panel.

OPERATING PROCEDURES

Operating Modes
The Sublimation Controller can be operated in the MANUAL,
AUTOMATIC, REMOTE SET and AUTOMAT/REMOTE mode.
In MANUAL and AUTOMATIC modes all the controls are given
on front panel.
In AUTOMAT/REMOTE and REMOTE SET, the controls are
given via signals coming through the I/O cable.
NOTE
After a power failure the Sublimation Controller will return to the
previously selected operating mode. If ìAUTOSTARTî parameter
was set on ìYESî and before the power failure the unit was in
sublimation mode, the sublimation starts on again automatically.
The unit is designed to operate in two different modes:
with manual selection of the parameters (MANUAL and
REMOTE SET modes)
with automatic selection of the parameters (AUTOMATIC
and AUTOMAT/REMOTE modes)
The Sublimation Controller can be used to control the TSP or
Mini Ti-Ball pumps type.
In MANUAL and REMOTE
sublimation parameters are setting by the user by means of the
front panel controls (MANUAL mode) and/or by signal send on
the I/O connector (REMOTE mode).
If the Sublimation Controller is used in conjunction with the TSP
pump the TSP source type must be set. If the Sublimation
Controller is used in conjunction with the Mini Ti-Ball pump the
Mini Ti-Ball source type must be set.
LCD back lighted alphanumeric display dot matrix, 16 characters, 2 rows.
Green LEDs that show:
if ON, the relevant TSP pump filament selected;
if blinking, the relevant TSP pump filament interrupted.
Key for manual selection of one TSP pump filaments.
Key for controller operating mode selection:
OFF when ìParameters Settingî mode is activated;
ON when ìSublimationî is activated.
Green LED that show:
if ON, that controller status is in waiting time between two sublimation or during current leading
edge;
if blinking, the sublimation is in phase.
Green LED ON when Mini Ti-Ball operating mode is selected.
Key that, depending on condition:
confirm the start of sublimation;
memorize the selection made;
reset a fail status.
Key that, depending on condition:
select the operating mode (MANUAL, AUTOMATIC, AUTOMAT/REMOTE and REMOTE SET);
escape from the parameters setting pages without changing the parameters.
Keys used to modify the values in the parameters setting pages.
SET operating modes
the
Control/Indicator Description
1. Connector to plug the optional cable for TSP or Mini Ti-Ball
connection
2. RS 232-422-485 connector (optional)
3. Power cord socket, input voltage selector, protection fuses
4. Power switch: ON (I)/OFF(O)
5. I/O signals connector
Sublimation Controller rear panel
15
INSTRUCTION FOR USE
87-900-077-01(B)