Place the installation box outer part and inner part on top of
each other and fix with 7 screws (3.5 x 9.5) – right installa-
tion (R) and left installation (L).
Fix the fan(s) (20) with 3 screws each (3.5 x 19) to the instal-
lation box. If a fan is not mounted, the screws still need to
be screwed in to prevent the installation box rattling.
Place the supports (60) onto the nozzles (1a) in the installa-
tion box and click in place.
Internal control panel
push the control panel cable (23 – silicone) for the fan
through the recess in the support and clamp in the foreseen
cable guide.
External control panel
the control panel cable(s) (not illustrated) may not
against the heating, the fan or hot air pipe. Fix the cables
sufficiently.
Fix the installation box in the installation cut-out with
6 screws (3 x 12) inclined outwards. If this is not possible,
the installation box can be fixed at the side on the top end
of the installation cut-out with 4 screws.
Fix the support (60) with 4 screws (3.5 x 16).
Slide the blend (61) on from the front until clicks in.
1a
2
3 x
23
60
1a
7
61
16
20
1
2 x
3 x
2 x
R
4 x
L
20
4 x
60

Install the heating

S 3004 / S 3004 P

Fig. A (right installation) / fig. B (left installation)
The thermostat sensor (5) must always be mounted to
the heating (room side) from the front. The thermostat
sensor (5) and capillary pipe (6) may never be against the heat
exchanger or on the heating cover and may never be bent!
For left installation only
Carefully take the thermostat sensor (5) off the clips and place
on the opposite side (mirror image) until it clicks in.
Place the heating in the floor cut-out.
Fix the unit with 5 screws (3) 5.5 x 25 to the pre-punched
points on the corners and front centre. Reinforce the floor
construction at the screw points, such as with spacers.
Remove the control rod (7) from the support (60), push
through the bush of the support and click into position in
the safety pilot valve (8).
3 x
5
* S 3004 P only
S 3004 P – preparation of the Piezo push
ignitor
Push the earth spring (14) out of the transport protection so
that it is against the installation box (otherwise the ignition
doesn't work).
Attach the ignition cable (16) on the pressure rod side using
the cable clip (17) of the installation box. Lay the ignition ca-
23
ble through the installation box and slide through the recess
in the support.
1a
The Piezo push ignitor must be installed on the side of the
control rod. Bend up the right (R) or left (L) earth contact of
the installation box.
7
60
*
16
17
8
16
6
*
16
L
R
14
3