Herunterladen Inhalt Inhalt Diese Seite drucken

Making Settings; Replacement Parts; Disposal Note - Grohe 36 456 Montageanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Making settings

Setting the running time, see fold-out page 64.
Setting the programme, see fold-out page 65.
*A: Cleaning mode: The water flow can be temporarily
locked.
*B: Interval of automatic flushing, usage-independent.
*C: Interval of automatic flushing, usage-dependent.
*D: Runtime of automatic flushing.
*E: Runtime of thermal disinfection.
Maintenance
, see fold-out page 66.
• Shut off hot and cold water supply.
• Disconnect voltage supply.
• Inspect and clean all parts, replace if necessary and
lubricate with special grease.
Thermostatic compact cartridge
Readjustment is necessary after each maintenance
operation on the thermostatic compact cartridge (see
Adjustment).
Fault / Cause / Remedy
Fault
Water not flowing
Undesired water
flow
Flow rate too low
Water temperature
too high or too low
Cause
• Filter in solenoid valve blocked
• Solenoid valve defective
• Plug-in connector without contact
• No voltage
- Power supply unit defective
- Power supply switched off
• Automatic flushing activated
• Solenoid valve defective
• Head shower dirty
• Filter in solenoid valve dirty
• Flow temperature incorrectly set
• Dirty filters or defective non-return valve
In order to ensure long-term protection from scalding, at
least once a year must be checked that the pre-adjusted
outlet temperature is not exceeded.

Replacement parts

see fold-out page 1 (* = special accessories)
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.

Disposal note

This category of device does not belong in the
domestic waste, but must be disposed of separately
in accordance with the relevant national regulations.
Remedy
- Clean filter
- Replace solenoid valve
- Check plug-in connector
- Replace power supply unit
- Switch on voltage supply
- Wait 1 - 10 minutes
- Replace solenoid valve
- Clean head shower
- Clean filter
- Adjust thermostatic cartridge
- Replace filters and non-return valve
8

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis