Herunterladen Inhalt Inhalt Diese Seite drucken

Wilo Safe WS 5-24 Yonos PICO Einbau- Und Betriebsanleitung Seite 17

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Item 3: Yonos PICO Plus 25/1-6 -N circulation
pump Secondary circuit
Material: Stainless steel, cable length 2 m
Item 4: 2.5 bar safety valve, ½" female thread
Item 5: 0-4 bar pressure gauge on the return
side of the secondary circuit, ?" male
thread on reverse, screwed into flat seal-
ing ?" shut-off valve.
Item 6: Filling and drain cock, ½"
Secondary circuit
Item 7: Union inserts, 1" female thread x 1½"
female thread
Union nut, primary circuit.
Union inserts soldered joint Ø28 mm
x 1½" female thread union nut, second-
ary circuit.
Item 8: 90° pipe elbow, secondary circuit,
33x2.3 mm brass pipe.
With connection for safety valve (½"),
filling and drain cock (½") and immersion
well for pressure gauge (both sides ?").
Item 9: Thermometer on feed elbow of primary
circuit, inserted into immersion well.
Item 10: Manual ventilation valve, ¼" male
thread, flat sealing.
Item 11: Yonos PICO Plus 25/1-6 circulation pump
Primary circuit, cable length 2 m.
Item 12: 90° pipe elbow, primary circuit,
30x2 mm brass pipe.
With connection for ventilation valve
(¼") and thermometer immersion well
(both sides ¼").
Item 13: 3-way mixer 1½" male thread x 1½"
RCD x 1" male thread, brass, Kvs value
6.3, primary circuit. Manual operation,
scaling on both sides (0 to 10).
Automatic control through use of a ser-
vomotor (ESBE) available as option. An
adhesive label (red/blue) is enclosed with
the servomotor to be attached to the
control button according to whether
Wilo-Safe is installed to the right or left.
Item 14: Thermal insulation shell (material EPP,
material class B 2 acc. to DIN 4102 T 1).
Split in two and with pre-stamped cut-
out forms. These can be cut out if Wilo-
Safe is installed the other way around,
making it easy to rotate the valves by
180°.
Item 15: Wall bracket, screwed onto the wall with
the help of dowels.
Wilo-Safe is attached to the two square
bolts on the wall bracket via the corre-
sponding drilled holes on the reverse of
the multipurpose fittings and secured by
the springs.
Dimension drawing of Wilo-Safe WS 5-24 cpl
(Fig. 2).
All parts are made of red brass/brass. They are
connected with pipe threads and flat gaskets.
Installation and operating instructions Wilo-Safe WS 5-24 Yonos PICO
WSG basic unit (Fig. 3)
Essentially, the basic unit consists of the heat
exchanger and the connecting fittings for the sec-
ondary side (underfloor heating circuit).
Specifically, the basic unit consists of the follow-
ing components (Fig. 1):
Item 1: WT heat exchanger
made of Z35 (Cu Zn 36 Pb 2 As), connec-
tion for primary side on heat exchanger:
Feed: R 1¼
Return: R 1½
Feed and return connection for second-
ary side, each: Rp 1½ MS
Item 2: Two shut-off ball cocks as check valves
with integrated thermometer 0-120°C,
Ø63 and Rp ¾ connection nipple or dia-
phragm expansion tank for feed and
return connection
Item 3: Yonos PICO Plus 25/1-6 -N circulation
pump, secondary circuit
Material: Stainless steel, cable length 2 m
Item 4: 2.5 bar safety valve
Item 5: 0-4 bar pressure gauge on return side
Item 6: Filling and drain cock
Item 7: Union inserts with soldered joint Ø28mm
Item 8: MS feed elbow
Item 14: Thermal insulation shell, split
(material EPP, material class B 2 acc. to
DIN 4102 T 1)
WSA connection kit (Fig. 4)
The connection kit represents the feed part of the
primary side (boiler side). It consists of (Fig. 1):
Item 9: Thermometer 0-120°C, Ø63 mm
Item 10:Manual ventilation valve, ¼" male thread,
flat sealing
Item 11:Yonos PICO Plus 25/1-6 circulation pump,
primary circuit, cable length 2 m
Item 12:MS feed elbow with Rp ¼" threaded port
for ventilation valve
WSM mixer (Fig. 5)
The 3-way mixer (Fig. 1, item 13) R 1" MS (setting
angle 90°) can be used to control the temperature
of the feed water on the boiler side flowing into
the heat exchanger so that colder water flows in
from the reverse side. The screwed connections fit
the connections for the basic unit and the con-
nection kit. Mixer control can be automated using
a servomotor. Servomotors from Wita, Tekmar and
ESBE can be connected directly to the mixer.
If a servomotor is connected to Wilo-Safe, the
motor head of the primary circuit pump has to be
rotated 90° to the right. In addition, the insulating
shell has to be cut out as per the marked surfaces
(Fig. 1).
English