Herunterladen Inhalt Inhalt Diese Seite drucken

Product Information; Description And Function - Wilo Safe WS 5-24 Yonos PICO Einbau- Und Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

English

5 Product information

5.1 Type key
Example:
WS
5-24
Yonos PICO
5.2
Technical data
Rated power:* e.g.
Secondary side
(underfloor heating circuit)
Temperature: feed
Primary side
Temperature: feed
Max. operating pressure
Max. operating temperature
Total weight
* values rounded. See the dimensioning tables for your system's transmission
capacities (available on request).
5.3 Scope of delivery
System separation WS5-24 Yonos PICO
The system separation is packed in the insulated
container, assembled and pressure-checked.
The following parts are included:
• Safety valve
• Fastening element with 2 locking pins
• 2 union inserts with soldered joint Ø28mm x 1½"
RCD, secondary circuit
• 2 union inserts 1" female thread x1½" RCD,
primary circuit
• Installation and operating instructions for system
separation
• Installation and operating instructions for
Yonos PICO Plus circulation pump
WSG basic unit
The basic unit is packed in the insulated container,
assembled and pressure-checked.
The following parts are included:
• Safety valve
• Fastening element with 2 locking pins
• 2 union inserts with soldered joint Ø28mm x 1½"
RCD, secondary circuit
• Installation and operating instructions for system
separation
• Installation and operating instructions for
Yonos PICO Plus circulation pump
WSA connection kit
• Fully assembled connection kit
• Installation and operating instructions for
Yonos PICO Plus circulation pump
12
WS 5-24 Yonos PICO
Wilo-Safe system separation
Thermal output 5-24 kW
Pump used: Yonos PICO Plus
up to max. 26 kW
for:
3
Q = 2.2 m
/h
T
= 45 °C
V
return
T
= 35 °C
R
Q = 1.1 m³/h
T
= 80 °C
V
return
T
= 60 °C
R
6 bar (600 kPa)
90°C
14.6 kg
WSM mixer
• Mixer enhancement
• Installation and operating instructions for mixer
5.4 Accessories
Accessories must be ordered separately:
• Wilo-Safe servomotor 230 V, 50 Hz, 6.5 VA, 5 Nm,
setting angle 90°
See catalogue for a detailed list.

6 Description and function

6.1 Description of the product
The entire unit can be packed into the two insu-
lating shells.
The advantages of system separation for under-
floor heating are:
• No muddying of the heating system as a whole
• The heat exchanger itself does not require venting
• The entire system separation is made of corro-
sion-resistant material
• The screwed connections make the system
exceptionally easy to install
• Right or left-hand installation easy
• The foam shell (Wilo-Safe) is both thermal insula-
tion and an installation aid.
The parts described below are supplied as a com-
plete system separation unit.
Wilo-Safe components (Fig. 1)
Item 1: Heat exchanger
Cladding material is brass, Ø100 mm
external, ribbed coil of copper pipe
Ø22mm external.
Primary circuit ready for connection
(boiler side) via pipe coil each with 1 ½"
external thread connection for feed and
return, and 1" male thread for bypassing
the 3-way mixer.
Secondary circuit ready for connection
(underfloor heating circuit) via sheathing
of heat exchanger with 1 ½" male thread
for feed and return.
Item 2: Multipurpose fitting
1½" RCD x 1½" male thread x ¾" male
thread x ¾" male thread
As shut-off ball cock for feed and return
of the secondary circuit.
Integrated thermometer in handle.
¾" male thread with cap for connecting
a diaphragm expansion tank. Including
immersion well for holding an additional
temperature sensor. On the reverse
there is a mounting fixture for the Wilo-
Safe's wall bracket. The valves have an
additional drilled hole in the check valve
to guarantee the function of a con-
nected diaphragm expansion tank when
the fitting is closed.
WILO SE 11/2019