253
2
Error 253: Can not finish X-/Y-Axis
IN-Movement Backup Source File.
254
2
Error 254: Can not finish X-/Y-Axis
IN-Movement
255
2
Error 255: Can not get System Time
256
2
Error 256: Can not get System Time
257
2
Error 257: LvWedge Current / Current too low
258
2
Error 258: Can not open Backup Source File.
259
2
Error 259: Can not open Backup Destination
File.
260
2
Error 260: Can not read Backup Source File.
261
2
Error 261: Can not write Backup Destination
File.
262
2
Error 262: Can not close Backup Destination
File.
263
2
Error 263: Can not close Backup Source File.
264
2
Error 264: Can not open Recovery Source File.
265
2
Error 265: Can not open Recovery Destination
File.
266
2
Error 266: Can not read Recovery Source File.
267
2
Error 267: Can not write Recovery
Destination File.
268
2
Error 268: Can not close Recovery
Destination File.
269
2
Error 269: Can not close Recovery Source File. Machine Settings File on Memory Stick corrup-
278
2
Error 278: PWR_SUP_LVW / current too low
279
2
Error 279: LvWedge Voltage / Voltage too low
290
2
Error 290: Supervision, EL6080 NOVRAM,
Load: FB Read/Write busy for t>200ms
291
2
Error 291: Supervision, EL6080 NOVRAM,
fbWrite.bError
In InManState()
Check if parameter settings are correct or X-Y-
Axis is mechanically blocked
In InState()
Check if parameter settings are correct or
X-Y-Axis is mechanically blocked, check Aham
right enable setting
In PIcTime()
Can not get System Time
In PIcTime()
Can not set System Time
In LvWedge ()
Error occured in Current Measurement. Check
connection between Shunt and PLC
Machine Settings File on PLC (SPS) corrupted.
Do recover your Data from your Memory Stick.
Missing Memory Stick.
Machine Settings File on PLC (SPS) corrupted.
Do recover your Data from your Memory.
Missing Memory Stick.
Missing Memory Stick.
Machine Settings File on PLC (SPS) corrupted.
Do recover your Data from your Memory.
Machine Settings File on Memory Stick corrup-
ted. Do backup your Data from PLC (SPS) to
Memory Stick.
Machine Settings File on PLC (SPS) corrupted.
Machine Settings File on Memory Stick corrup-
ted. Do backup your Data from PLC (SPS) to
Memory Stick.
Machine Settings File on PLC (SPS) corrupted.
Machine Settings File on PLC (SPS) corrupted.
ted. Do backup your Data from PLC (SPS) to
Memory Stick.
In LvWedge()
Power Supply lacks in weld current. Power
Supply needs maintenance or low setting in
Energy parameter
In LvWedge()
Error occured in Voltage Measurement.
Check connection between Wedge and Wedge
holder. Wedge is broken or damaged.
Can not read Meter Hours during Startup of
Supervision Extension.
Shutdown SEAMTEK W-AT Machine and
restart.
fbWrite Error in INIT State of EL6080.
Shutdown SEAMTEK W-AT Machine and
restart.