REMEMBER
• Our mixers must be installed by professional installers in accordance with current regulations
and recommendations in your country, and the specifications of the fluid engineer.
• Sizing the pipes correctly will avoid problems of flow rate, pressure loss and water hammer
(see calculation table in our brochure and online at www.delabie.com).
• Protect the installation with filters, water hammer absorbers and pressure reducers to reduce
the frequency of maintenance (recommended pressure: 1 to 5 bar).
• Install stopcocks close to the mixer to facilitate maintenance.
• The pipe work, stopcocks, check valves and all sanitary fittings should be checked at least once
a year, and more frequently if necessary.

SERVICING AND CLEANING

• Cleaning chrome:
Do not use abrasive, chlorine or acid-based cleaning products. Clean with soapy water using a cloth
or a sponge.
• Frost protection:
Drain the pipes and operate the mixer several times to drain any remaining water.
MAINTENANCE
Removing the mechanism (fig. 3) :
• Unscrew the grub screw E (without fully removing it) using a 2.5mm Allen key.
• Unscrew the head F two full turns then shut-off the Hot and Cold water supply and continue to unscrew
the head F (fig. 3) to remove the mechanism.
Foreign bodies in the pipe work may cause the mechanism to malfunction:
- Automatic shut-off takes too long or there is continuous flow (fig. 8) :
• Clean the inside of the delay case L using a clean, dry cloth and clean the calibrated groove M
with a non-metallic, sharp point.
• Check that the lip seal N and the seats O are in good condition.
• Don't forget to replace the spring P.
- Dripping or a constant trickle (fig. 8):
• Clean the seats O or replace if damaged.
• Don't forget to replace the spring P.
BEWARE: do not grease the inside of the mechanism.
- Problems with achieving the correct temperature (fig. 1):
• Ensure that the hot and cold water pressures are balanced (ΔP < 1 bar)
• Check that there are no foreign bodies in the non-return valves A.
• Check the non-return valves at least once a year.
For Delabie UK Ltd market only: Tel. +44 (0)1491 824 449 email: technical@delabie.co.uk
For all other markets: Tel.+33 3 22 60 22 74 email: sav@delabie.fr
The most recent version of this installation guide is available on: www.delabie.com
After Sales Care and Technical Support:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis