Installation
Material losses
!
The strainer must be fitted for the appliance to func-
tion.
» When replacing an appliance, check whether
the strainer is installed (see chapter "Installa-
tion / Maintenance").
Removing / replacing the flow limiter
Note
Never remove the flow limiter if you are using a ther-
mostatic valve.
1 Plastic profile washer
2 Flow limiter
» Remove the flow limiter. Re-insert the plastic profile
washer.
DDLE Basis 18/21/24: Replace the flow limiter
» If 24 kW connected load has been selected, replace
the fitted flow limiter (white) with the flow limiter sup-
plied (orange, fixed to the cold water pipe).

Making the electrical connection

WARNING Electrocution
Carry out all electrical connection and installation
work in accordance with relevant regulations.
WARNING Electrocution
The connection to the power supply must be in the
form of a permanent connection in conjunction with
the removable cable grommet. Ensure the appliance
can be separated from the power supply by an iso-
lator that disconnects all poles with at least 3 mm
contact separation.
WARNING Electrocution
Ensure that the appliance is earthed.
Material losses
!
Observe the type plate. The specified voltage must
match the mains voltage.
» Connect the power cable to the mains terminal
(see chapter "Installation / Specification / Wiring
diagram").
DDLE Basis 18/21/24: Re-plugging the coding
card
In its delivered condition, the appliance is plugged to
21 kW. When changing to a different connected load,
carry out the following steps:
24
L1 '
2
1
2
» Re-plug the coding card according to the actual
connected load (for connected load options and fuse
protection of the appliance, see chapter "Installation /
Specification / Data table").
» Tick the selected connected load on the type plate.
Use a ballpoint pen to do this.
Fitting the base part of the back panel
3
L3 '
4
L2 '
1
L1 '
2
» Fit the base part into the back panel. Click the lower
back panel section into place.
» Align the mounted appliance by undoing the fixing
toggle, aligning the power supply and back panel,
and then re-tightening the fixing toggle. If the appli-
ance back panel does not rest against the wall, you
can secure the appliance with two additional screws
(see chapter "Installation / Installation options /
Water installation on finished walls").