Herunterladen Inhalt Inhalt Diese Seite drucken

CAME ZD2 Betriebsanleitung Handbuch Seite 11

Vorschau ausblenden Andere Handbücher für ZD2:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 21
Adjustment Trimmer
C
- «A.C.T.»
Sets the waiting time while open. Once this time has elapsed, closing automatically takes place.
The waiting time may be set from 1 to 150 seconds.
- «PAR.OP.»
Sets the gate's partial opening. By pushing the partial opening button connected at 2-3P, the
gate opens depending on the length of the gate.
- «SLOW S.» Sets the amperometric sensitivity that controls the force generated by the motor during slow
down; if the force exceed the set level, the system intervenes by inverting the direction of
motion.
- «RUN S.»
Sets the amperometric sensitivity that controls the force generated by the motor during
movement; if the force exceeds the set level, the system intervenes by inverting the direction of
motion.
- «SLOW V.» Sets the gate's fi nal opening/closing phase slow-down speeds.
- «RUN V.»
Sets the gate's opening/closing motion speed.
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.