Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Connections - CAME ZD2 Betriebsanleitung Handbuch

Vorschau ausblenden Andere Handbücher für ZD2:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 21

Electrical connections

L-N
Power supply 230V (AC) 50/60 Hz
10-11 Terminals for powering 24V (AC) accessories
10-E1 Movement fl ashing light (socket rating: 24V - 25W max.)
10-5
Open gate indicator-light (socket rating: 24V - 3W max.)
2-C1 Re-open during closing (NC) contact
2-C3 «partial stop» (NC) contact
2-C7 «Open while closing»(NC) contact "sensitive edges"
2-C8 «Close while opening» (NC) contact "sensitive edges"
M-N
24V (DC) motor with encoder
Electrical connection to operate the photocells' safety test
(DOC)
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
F-FA
Opening limit switch
F-FC
Closure limit switch
1-2
Stop button (NC) contact
2-3P Keyswitch and/or partial opening button (NO)
2-7
Commands button (NO)
B1-B2 Possible output of the radio receiver's second channel (NO).
Socket rating: 5A-24V (DC).
Connection of antenna
- Set DIP switch 7 to ON to activate the test.
(DIR)
IMPORTANT:
When the safety test function is activated, the NC contacts:
- If unused – are to be excluded on their relative DIP switches.