6. CONNECTION OF THE COMBUSTION AIR PIPE
Connect a 50 mm rubber pipe or similar conduit to the combustion air inlet at the
back of the stove, see figure 11. The other end of this rubber pipe or similar chan-
nel must draw in clean air from the outside. See figures 8 and from 9A to 9E.
7. COMPULSORY ROOM VENTILATION WHEN USING THE
STOVE
Make sure the room is sufficiently ventilated with fresh air. An additional 50 m³
of air is required every hour, over and above the normal room ventilation require-
ment.
Ventilation openings must be near the floor. Choose the location carefully. The
ventilation openings must not be blocked (neither inside nor outside).
Ensure that there is an opening for fresh air in the room with a section of at least
a quarter of the exhaust pipe section, with a minimum of 100 cm².
If the stove is located in rooms with mechanical ventilation, the following guide-
lines apply:
Mechanical
If the stove is located in rooms with mechanical ventilation, the following guide-
[m
lines apply:
<50
50 – 100
101 – 150
8. POSITION THE UNIT
1.
4
106
• Make sure that the position of the fresh air inlet always complies with
local legislation!
• Make sure that the fresh air inlet for combustion gas is covered, for
example, by a grille that prevents accessing it.
Always ensure that the combustion air duct can draw clean air from the
outside.
The stove cannot be used if an air suction system, a hot air heating sys-
tem or other appliances that affect the air pressure in the room, are used.
Such equipment must be disconnected.
ventilation
/h]
3
Never install the unit or carry out maintenance work on it if it is plugged
into the mains socket. Always make sure that the stove is disconnected
from the mains!
When it comes to the final positioning of the stove, make sure that the floor
capacity
Additional ventilation section re-
quired [cm
]
2
140
280
420