Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data - Eliwell Coldface EWRC300LX Bedienungsanleitung

Kühlzellenregler für installation in kühlzelle
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 32

TECHNICAL DATA

DESCRIPTION
Front panel
Container
Dimensions
Mounting
Connections
Operating temperature
Storage temperature
Operating humidity
Storage humidity
Display range
Analogue Inputs
Digital inputs
Relay outputs
Buzzer
Serials
Accuracy
Resolution
Power draw
Power supply
WARNINGS
Important! Make sure the machine is switched off before working on the electrical
connections.
The instrument is equipped with:
• Removable screw terminals: for connecting electric cables of 2.5 mm
section (one wire per terminal in the case of power connections): for the capacity of the terminals,
see the label on the instrument. The relay outputs are voltage free: they are indicated on the
board with the letters COM for Common, NO for Normally Open and NC for Normally Closed
contact. When current exceeds 8A on relay outputs, 2 x 2.5mm
for each individual contact to ensure the temperature of the cables does not exceed 85°C.
• Fastons: double row of fastons in series.
Do not exceed the maximum permitted current; for higher loads, use a contactor with sufficient
power capacity.
Make sure that power supply is of the correct voltage for the instrument.
Probes have no connection polarity and can be extended using a normal bipolar cable (note that the
extension of the probes influences the instrument's electromagnetic compatibility (EMC): take great
care with the wiring). Probe cables, power supply cables and the TTL serial cables should be routed
separately from power cables.
EWRC300/500LX
wall mounting (centre distance of holes A-B 181.0 mm; holes C-D 196.5 mm.
• removable screw terminals for serial port RS-485, digital and analogue inputs
• removable screw or FASTON terminals for power supply and digital relay outputs (see Wiring Diagrams)
internal housing for door lock disconnecting switch, remote control switch, etc.
WARNING: do not exceed the amperage limits specified on the door lock disconnector markings
–50...110 (NTC) / –55...150 (PTC) without decimal point, on display with 3 digits + sign
3 NTC inputs. PTC selectable by parameter H00
2 voltage-free digital inputs configurable by parameters H11/H12
Model EWRC300LX
• OUT1 output SPST 2HP 12(12)A 250Va
• OUT2 output SPDT 1HP 8(8)A 250Va
• OUT3 output SPST 1/2HP 8(4)A 250Va
• 1 TTL port for connection to TelevisSystem
• 1 RS-485 serial port for connection to TelevisSystem
IP54
Bayblend FR 110
front 210x245mm, depth 90mm
See Mechanical Installation paragraph)
-5°C...+50°C
-20°C...+85°C
10...90% RH non-condensing
• OUT1 output SPST 2HP 12(12)A 250Va
• OUT2 output SPDT 1HP 8(8)A 250Va
• OUT3 output SPST 1/2HP 8(4)A 250Va
• OUT4 output SPDT 1/2HP 8(4)A 250Va
• OUT5 output SPST 1HP 8(8)A 250Va
only on models where this is provided
• 1 TTL port for connection to Copy Card
(use with optional plug-in module)
better than 0.5% of end of scale +1 digit
1 or 0,1 °C
14W
230Va ± 10% 50/60Hz
cables (2 fastons) must be run out
2
Model EWRC500LX
maximum cross
2
10 - EN

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Coldface ewrc500lx

Inhaltsverzeichnis