Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data - Bosch PLL 1 P Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für PLL 1 P:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
18 | English
A)
(13) Tripod
(14) Holder
(15) Metal surface for line operation
(16) Metal surface for point operation
(17) Adjusting screw of the holder
(18) 1/4" tripod mount on holder
A) Accessories shown or described are not included with the product as standard. You can
find the complete selection of accessories in our accessories range.

Technical data

Line laser
Article number
Working range up to approx.
– Line operation (with holder (14))
– Point mode
B)
Levelling accuracy
Operating temperature
Storage temperature
Max. altitude
Max. relative air humidity
Pollution degree according to IEC 61010-1
Laser class
Laser type
C
6
Divergence
– Laser line
– Laser point
Batteries
Approx. operating time
Weight according to EPTA-Procedure 01:2014
1 609 92A 56S | (26.08.2019)
A)
PLL 1 P
3 603 F63 300
5 m
20 m
±0.5 mm/m
+5 °C to +40 °C
–20 °C to +70 °C
2000 m
90 %
C)
2
2
635–650 nm, < 1 mW
1
0.5 mrad (full angle)
0.6 mrad (full angle)
2 × 1.5 V LR3 (AAA)
15 h
0.14 kg