Herunterladen Inhalt Inhalt Diese Seite drucken

Cleaning And Maintenance; Technical Specifications - HQ Power VDP250MH14 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

Indicates that the magnetic indexing circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is
defective (or its drive circuit on the main PCB). The colour wheel is not located in the default position after the reset.
2 2 2 2 Err
Err : Rotating gobo wheel error
Err
Err
Indicates that the magnetic indexing circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is
defective (or its drive circuit on the main PCB). The gobo wheel is not located in the default position after the reset.
3 3 3 3 Err
Err : Rotating gobo indexing error
Err
Err
Indicates that the magnetic indexing circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is
defective (or its driver circuit on the main PCB). The rotating gobo is not located in the default position after the reset.
5 5 5 5 Err
Err : Pan yoke movement error
Err
Err
Indicates that the yoke's magnetic indexing circuit malfunctions (sensor failed or magnet missing) or the stepping-
motor is defective (or its driving IC on the main PCB). The yoke is not located in the default position after the reset.
6 6 6 6 Err
Err : Tilt head movement error
Err
Err
Indicates that the head's magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepping-
motor is defective (or its driving IC on the main PCB). The head is not located in the default position after the reset.
7 7 7 7 Err
Err : Prism wheel error
Err
Err
Indicates that the magnetic indexing circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is
defective (or its driver circuit on the main PCB). The prism wheel is not located in the default position after the reset.
10 10 10 10Err
Err : Fixed gobo wheel error
Err
Err
Indicates that the magnetic indexing circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is
defective (or its drive circuit on the main PCB). The fixed gobo wheel is not located in the default position after the reset.

7. Cleaning and Maintenance

1. All screws should be tightened and free of corrosion.
2. The housing, the lenses, the mounting supports and the installation location (e.g. ceiling, suspension, trussing)
should not be deformed, modified or tampered with e.g. do not drill extra holes in mounting supports, do not
change the location of the connections, ...
3. Mechanically moving parts must not show any signs of wear and tear.
4. The electric power supply cables must not show any damage. Have a qualified technician maintain the device.
5. Disconnect the device from the mains prior to maintenance activities.
6. Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents.
7. There are no user-serviceable parts, apart from the lamp (see "4. Installation" on p.2).
8. Contact your dealer for spare parts if necessary.

8. Technical Specifications

Power Supply
Power Consumption
Lamp
Motors
Dimensions
Total Weight
Max. Ambient Temperature
Max. Housing Temperature
9. Schematic
See p.38 at the back of this manual.
The information in this manual is subject to change without prior notice.
VDP250MH14
max. 230Vac/50Hz
max. 400W
1 x 230V / 250W MSD GY9.5 (order code LAMP50 MSD of LAMP250MSD/2)
11 micro motors
380 x 440 x 490mm
22kg
45°C
75°C
7