You can use the same starting address for a whole group of devices or enter an individual one for every device.
When all devices have the same address, all the ARAZU Is will "listen" to the control signal on one particular
channel. In other words: changing the settings of one channel will affect all devices simultaneously. If you set
different addresses, each device will "listen" to a separate channel number. Changing the settings of one channel will
only affect the device in question.
In the case of the 5-channel ARAZU I, you will have to set the start address of the first ARAZU I to 1, the second
ARAZU I to 6 (1 + 5), the third to 11 (6 + 5) and so on.

7. Cleaning and Maintenance

1. All screws should be tightened and free of corrosion.
2. The housing, visible parts, mounting supports and the installation location (e.g. ceiling, suspension, trussing)
should not be deformed, modified or tampered with e.g. do not drill extra holes in mounting supports, do not
change the location of the connections.
3. Moving mechanic parts must not show any signs of wear and tear.
4. The electric power supply cables must not show any damage. Have a qualified technician maintain the device.
5. Disconnect the device from the mains prior to maintenance activities.
6. Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents.
7. There are no user-serviceable parts.
8. Contact your dealer for spare parts if necessary.

8. Technical Specifications

Power Supply
Power Consumption
Fuse
DMX512
Connection
LEDs
Dimensions
Total Weight
Max. Ambient Temperature
Max. Housing Temperature
Use this device with original accessories only. Velleman nv cannot be held responsible in the event of
damage or injury resulted from (incorrect) use of this device. For more info concerning this product, please
visit our website www.hqpower.com. The information in this manual is subject to change without prior
notice.
VDPL300SC
All manuals and user guides at all-guides.com
max. 230 VAC / 50 Hz
25 W
F1A, 250 VAC (5 x 20 mm) (order code FF1N)
5 channels
3-pin XLR
48 pcs (24 x red, 12 x green, 12 x blue)
370 x 210 x 140 mm
3.3 kg
45°C
50°C
6
HQPOWER

Werbung