f. Function selection
Different functions can be set by means of the 3 push buttons and the display. When you switch the device on, the
display setting will be the same as before you turned it off.
Procedure: • Press the ENTER button for 3 seconds, the display will start flashing
• Press the UP button to select a different function
• Press ENTER to confirm the selected function or EXIT/DN to cancel
• The active function will flash. Switch it on or off using UP or EXIT/DN button
• Press ENTER again to confirm your settings
• Press EXIT/DN to save the setting and exit the menu
Please refer to the list below for the different settings:
S/N
Function
Option
display
select
0
A A A A - - - - - - - - - - - -
A001...A511
1
Run
Run
ON / OFF
Run
Run
2
Focu
Focu
ON / OFF
Focu
Focu
3
Disp
Disp
Disp
Disp
DP - x
4
RDIS
RDIS
RDIS
RDIS
ON / OFF
5
Rpan
Rpan
Rpan
Rpan
ON / OFF
6
Rtilt
Rtilt
Rtilt
Rtilt
ON / OFF
Rest
Rest
ON / OFF
7
Rest
Rest
8
Inda
Inda
ON / OFF
Inda
Inda
9
Lamp
Lamp
ON / OFF
Lamp
Lamp
10
Ver
Ver
Ver
Ver
V – 1.0
11
Time
Time
Time
Time
OPEN
CLR
12
Test
Test
Test
Test
tE – 1
tE – 16
13
Cont
Cont
Cont
Cont
CN – X
14
Edit
Edit
Edit
Edit
SCE1
SCE15

6. Error Messages

When the device is switched on, it will make a reset first. The display may show "XERR" if there are problems with one
or more channels. "X" stands for any channel equipped with a position test sensor. For example, "2Err" means there
is an error in channel 2. Simultaneous errors on channels 1, 2 and 5 are shown as "1Err", "2Err","5Err" flashing
repeatedly for 5 times and then the device will reset all the stepper motors and generate a signal. If the errors remain
after 3 attempts, the device stop functioning if there are 3 or more errors. If there are less than 3 errors, the device
can still be operated with the exception of the erratic channels.
1 1 1 1 Err
Err
Err : Colour wheel error
Err
VDP250MH14
Return to main
menu
Par-1
Par-n
TIME
CNIN
Parl
Par-N
TIME
CNIN
Display
Axxx
DMX start address setting
RUN
Run pre-installed programme in the EEPROM
Focus, opens the shutter, selects white light
Dxxx
Display the DMX value for each channel
Reverse display
Reverse pan
Reverse tilt
Reset
Install software into the EEPROM
Lamp ON/OFF control
Software version
Xxxx
Lamp work time (future releases only)
Reset lamp work time
Test the function of each channel
1 1 xx
Edit a scene without controller
1 N xx
1 T – X
The run time of that scene
ON/OFF
Edit a scene through a controller
F 1 xx
Edit a scene without controller
F N xx
F T – X
The run time of that scene
ON/OFF