If not, invert clamps V and W on the motor terminal board of the interested motor.
After having carried out the various connections and having supplied voltage, all the LEDS
are switched off.
The motor opens and closes, but it has no strength and moves slowly.
The gate opens but does not close after the time set.
The gate does not open or close by activating the various K and RADIO buttons.
By activating the K button the gate does not move.
The electric lock does not work.
ACCESSORIES -
For the connections and the technical data of the optional equipments follow the relevant handbooks.
CODE LEARNIG SYSTEM RADIORECEIVERS
RX433/A
super eterodyne and coupling
RX433/A
super eterodyne and terminal board
RX433/A 2CH super eterodyne, 2 channel and coupling
RX433/A 2CH super eterodyne, 2 channel and terminal board
FAULT
code ACG5055
code ACG5056
code ACG5051
code ACG5052
Check the integrity of fuses F1 and F2. In case of interrupted fuse use only of adequate value
F2 = 5A
F1 = T315mA.
Check trimmers TORQUE and LOW-SPEED adjustment.
Ensure to have set DIP 3 at ON. Button K BUTTON always inserted in automatic functioning
mode (DIP 6 OFF). Replace button or switch of the selector switch.
Failed edge self-test => check the connections between electronic board and edge feeder.
Attention: if not using a feeder for edges, DIP 10 must be at OFF position.
Faulty safety edge contact. Faulty photocells contact with DIP 4 OFF.
Fix or replace the relative contact.
Impulse K always inserted. Check and replace any buttons or micro-switches of the selector switch.
Ensure to have enabled DIP 8 at ON.
RADIO TRANSMITTER SUN
SUN 2CH
code ACG6052
SUN CLONE 2CH
code ACG6056
PUSH-BUTTON FLAT
Connection to motor
Connection to control panel
33
SOLUTION
SUN 4CH
code ACG6054
SUN CLONE 4CH
code ACG6058
code ACG2012
code ACG2013
G
B