G
B
R50 INSTALLATION
PRE-INSTALLATION CHECKS
The leaf must be fixed firmily on the hinges to the pillars, must not be flexible during the
movement and must move without frictions. The ground on which the R50 wheels run must be
solid and compact with minimum gradient.
Gate features must be uniformed with the standards and laws in force. The door/gate
can be automated only if it is in a good condition and its conditions comply with the EN 12604
norm.
- The door/gate leaf does not have to have a pedestrian opening. In the opposite case it is
necessary to take the appropriate steps, in accordance with EN 12453 norm (for instance; by
preventing the operation of the motor when the pedestrian opening is opened, by installing a
safety microswitch connected with the control panel).
- No mechanical stop shall be on top of the gate, since mechanical stops are not safe enough.
R50 INSTALLATION
The ground should be compact and without any excessive differences in level along the tract
destined for wheel run.
Position the gate about halfway, secure the gearmotor plate to the corner of the gate leaf and
ensure that the drive wheels rest on the ground.
Drill four Ø 6.5 mm holes in the leaf, then tap them with M8 male threading.
Insert four M8 bolts and tighten with a No. 13 wrench.
Remove the elastic pin which prevents the wheels from turning (Fig. 6).
If the drive wheels slide on the ground during operation, turn the set screw on the spring
D
Parts to install meeting the EN 12453 standard
Skilled persons
COMMAND TYPE
(out of public
with manned
operation
with visible impulses
(e.g. sensor)
with
not
visible
impulses
(e.g. remote control
device)
automatic
C and D, or E
* a typical example are those shutters which do not have access to any public way
A: Command button with manned operation (that is, operating as long as activated),
like code ACG2013
B: Key selector with manned operation, like code ACG1010
C: Adjustable power of the motor
D: Safety strips and/or other safety devices to keep thrust force within the limits of
EN12453 regulation - Appendix A.
E: Photocells, like code ACG8026 (To apply every 60÷70cm for all the height of the
column of the gate up to a maximum of 2,5m - EN 12445 point 7.3.2.1)
clockwise to increase the pressure between the wheels and the ground.
To reduce wheel wear during operation, loosen nuts (D) with a No. 13 wrench and tilt the
rubber wheels so that the axles coincide with the center of the gate leaf pivot point.
The wheels may be tilted by 0° to 7.5°. Retighten the two nuts.
The R50 is equipped with two waterproof, armored limit stops to electrically control gate
travel.
The limit stops should be positioned in accordance with installer requirements.
B min [m]
B [m]
Opening time [sec] = 7,85 x L
26
USE OF THE SHUTTER
Skilled persons
Unrestricted use
(public area)
area*)
A
B
C or E
C or E
C or E
C and D, or E
C and D, or E
= (0,205+A) / 0,12
= 0,9 x L
non possibile
C and D, or E
C and D, or E
C and D, or E
3