Herunterladen Inhalt Inhalt Diese Seite drucken

RIB R50 Bedienungsanleitung Seite 27

Vorschau ausblenden Andere Handbücher für R50:
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

R50 APPLICATION ON MULTIPLE PANEL DOORS
In this case the R50 must be installed on the first leaf.
Limit switch
Internal
Limit switch
Box
External
EMERGENCY RELEASE
To be undertaken after disconnecting power supply.
In the event of a power failure, raise the side handle to lift the wheels off the ground.
In order to carry out the manual operation of the gate leaf the followings must be checked:
- That the gate is endowed with appropriate handles;
- That these appropriate handles are placed so to avoid safety risks for the operator;
- That the physical effort necessary to move the gate leaf should not be higher than 225 N, for doors/gates for
private dwellings, and, 390N for doors/gates for commercial and industrial sites ( values indicated in 5.3.5 of
the EN 12453 norm
A
: Maximum stroke -2,4 cm / +1,6 cm during movement (holes or uneven ground)
B
: Remove the elastic pin, after the unit is secured, to release the spring.
C
: Spring set screw.
Wheels Ø120
250
Mechanical stopper
Box
Guide
27
G
B
Olive
4
5
6
Inhaltsverzeichnis
loading

Inhaltsverzeichnis