Setting the Parameter
On delivery, there are parameters set, which in most cases, make it possible to work with the suction unit
without problems. Only in individual cases, if this is not possible, the parameters can be changed.
EN
The setting of various parameters and the execution of a self-diagnosis are carried out in the program-
ming mode.
Please refer to the operating instructions on the Internet or Figs. D and E at the beginning of this
document to find out how to set the parameters and run self-diagnosis.
The display (24) shows which parameter are set:
/
In order to set the different parameters, the programming mode must be started and the parameter select-
ed.
To do so, press the mode key (21) and enter key (27), see Figs. D and E at the
beginning of this document.
Change values with the [-] key and [+] key.
Confirm and save settings with the Enter key (27). Successful saving is acknowl-
edged with an acoustic signal.
If a change is not to be applied, press the mode key (21) again to cancel.
Self Diagnosis (see Fig. D at the beginning of this document)
Start the self diagnosis manually. This is carried out once.
Acoustic signal (see Fig. D at the beginning of this document)
When on, various inputs are confirmed with an acoustic signal. This beep can be switched on and off.
Time interval for full display of the dust drawer (see Fig. D at the beginning of this
document)
After reaching a set time interval, a request appears to empty the dust drawer.
It is possible to select one of 5 different times.
Time interval / hrs
In the case of heavy dust generators (e.g. blasting equipment), the time interval "emptying the
dust drawer" should be set to 5 hours, if necessary to 10 hours.
Automatic switch-on for automatic operation (see Fig. E at the beginning of this
document)
The switch-on threshold, which activates and deactivates the suction function when a connected electrical
device is operated, can be set.
When setting the switch-on threshold for handpieces, the control unit must be switched on for the first
measurement (stand-by) without operating the handpiece
For the second measurement (On), the handpiece should be operated at the speed at which the suction
is to be switched on.
„d"
Perform self-diagnosis
„b"
Acoustic signal on / off (decimal point on / off)
„A"
Time Interval for "Full" Display Dust Drawer
„c"
Setting the automatic switch-on (calibration)
„t"
Set after-run (time) for the suction turbine
Value in display (24, Fig. 2)
2
5
10
50
100
1
2
3
4
Factory setting
5
- 4 -