Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

ENGLISH
Description of control panel
The ZE4 electric panel is suitable for con-
trolling the automation of EMEGA series
230V garage-type doors with up to 600W
power and 50-60 Hz frequency.
Wholly designed and built by CAME
S.p.A., it meets UNI 8612 regulations in
force. ABS Case with an IP54 protective
level, with air recycling inlet and trans-
former.
The circuit requires 230V (a.c.) at terminal
blocks L1- L2 and the inlet is protected
with two 5A fuses, whilst the low voltage
command devices are protected by a 2A
fuse.
The accessories' total wattage (24V) must
not exceed 20W.
The panel includes a manoeuvre pick-up
function. This function is activated during
the initial phase of the gate's opening and
closing.
Safety
Photocells can be connected to obtain:
- Re-opening during closure (2-C1), if the
photocells identify an obstacle while the
gate is closing, they will reverse the
direction of movement until the gate is
completely open;
- Total stop (1-2), shutdown of gate
movement without automatic closing; a
pushbutton or radio remote control must
be actuated to resume movement.
N.B: If an NC safety contact (2-C1, 1-2) is
opened, the LED (n°7, pag.8) will flash to
indicate this fact;
- Obstacle presence detection. When the
motor is stopped (gate is closed, open or
half-open after an emergency stop
command), the transmitter and the control
pushbutton will be deactivated if an
obstacle is detected by one of the safety
devices (for example, the photocells);
Accessories which can be connected
-Courtesy Light. A light that illuminates the

GENERAL CHARACTERISTICS

manoeuvring zone; after an opening com-
mand, the light remains on for a fixed time
of 5 minutes and 30 seconds, connect it to
terminal block E1-E3.
- Open gate pilot lamp. It is a light that in-
dicates the garage-type door's open posi-
tion and turns off when the gate activates
the closing end-stop.
- 24V electric lock, connect it to terminal
blocks 11-EB.
Other functions
- Automatic closing. The automatic closing
timer is automatically activated at the end
of the opening cycle. The preset,
adjustable automatic closing time is
automatically interrupted by the activation
of any safety system, and is deactivated
after a STOP command or in case of
power failure;
- "Operator present". Gate operates only
when the pushbutton is held down (the
radio remote control system is
deactivated);
- Limit switch opening. The door stops with
the help of the microswitch during the
opening phase, connect the microswitch to
terminal blocks F-FA and switch dip n°9 to
OFF;
- Pre-flashing. After an opening or closing
command, the flasher connected to the W-
E1 flashes for 5 seconds before beginning
the procedure;
- Type of command:
-Open-stop-close-stop by button and
transmitter;
-Open-close by button and transmitter;
-Open only by transmitter.
Adjiustments
- Operating time;
- Automatic closure time.
Caution! Disconnect the unit from
the main power lines before carrying out
any operation inside the unit.
-3-