Description of control panel
Control panel for 24V d.c. gear motors,
powered by 230V a.c. at 50-60 Hz (single-
phase).
Designed to control ATI, FERNI and FROG
gear motors.
Designed and built entirely by CAME
CANCELLI AUTOMATICI S.p.A., it meets
regulations in force and with IP 54 level of
protection.
Housing in ABS is equipped with vents to
provide internal air circulation. Guaranteed
24 months, unless tampered with.
This control panel is powered by 230V a.c.
across terminals L1 and L2, and is
protected by a 3.15A fuse on the main
power line. Control systems are powered
by low voltage and protected by a 630mA
fuse.
The total power consumption of 24V
accessories (which are protected by a
3.15A fuse) must not exceed 40 W.
Safety
Photocells can be connected to obtain:
- Re-opening during the closing cycle (2-
C1), if the photocells identify an obstacle
while the gate is closing, they will reverse
the direction of movement until the gate is
completely open;
- Partial stop, shutdown of moving gate,
with activation of an automatic closing
cycle (2-C3);
- Total stop (1-2), shutdown of gate
movement without automatic closing; a
pushbutton or radio remote control must be
actuated to resume movement).
-4-
GENERAL CHARACTERISTICS
- Safety test function. The control unit will
now check the safety system every time an
opening or closing command is given (see
p. 26).
The electrical panel includes an
amperometric sensor for the motors which
is triggered whenever an obstacle blocks
movement during opening or closing. If
operating speed, the sensor inverts the
movement direction. If it is slowing down,
one motor stops while the other completes
its movement. The sensor's sensitivity can
be adjusted using the trimmers (see p.12).
The transformers are equipped with a
guard, which in case of thermal overload
will keep the doors open.
They are closed again only after the tem-
perature falls below the emergency thresh-
old.
Accessories which can be connected to
this unit
- "Gate open" signal light;
- Flashing signal light when gate is in
motion
- Electric lock;
- LB18 circuit card for emergency battery,
which is automatically connected in case of
power failure; battery is recharged when
line power is restored
- Radiofrequency AF board (see table
pag.29).
Other functions available
- Automatic closing. The automatic closing
timer is automatically activated at the end
of the opening cycle. The preset,
ENGLISH