N OT E
For tubing, choose either the right or left tubing direction and
follow the steps below. This work can be made easier by
placing padding material (such as styrofoam) at the rear right
side of the indoor unit. (Fig. 3-59)
Padding material
Fig. 3-59
■ Right-side tubing
(1) Shape the refrigerant tubing so that it can easily go into the
wall hole. (Fig. 3-60)
Rear panel
Cover
Refrigerant
tubing
Inter-unit
wiring

Drain hose

Fig. 3-60
(2) Push the wiring, refrigerant tubing, and drain hose through
the hole in the wall. Adjust the indoor unit so it is securely
seated on the rear panel. (Fig. 3-61)
Fig. 3-61
(3) Carefully bend the tubing (if necessary) to run along the
wall in the direction of the outdoor unit and then tape as far
as the fittings. The drain hose should come straight down
the wall to a point where water runoff won't stain the wall.
(4) Connect the refrigerant tubing to the outdoor unit. (After
performing a leak test on the connecting part, insulate it
with the tubing insulation. (Fig. 3-62)
Insulation
Fig. 3-62
(5) Assemble the refrigerant tubing, drain hose, and inter-unit
wiring as shown in Fig. 3-62.
SUPPLEMENT
■ Left-side tubing
(1) Lead the tubing and drain hose through the wall, allowing
sufficient length for connection. Then bend the tubing using
a tube bender to make the attachment. (Fig. 3-63)
Rear panel
Hole in wall
Bent part
Gas tube
Liquid tube
Fig. 3-63
(2) Switch the drain hose and drain cap.
Switching drain hose and drain cap
(a) Locate the drain hose and the drain cap. (Fig. 3-64)
Drain cap
Drain hose
Fig. 3-64
(b) Remove the screws fastening the drain hose on the
right side, and pull out the drain hose to remove it.
(Fig. 3-64)
(c) Apply moderate force to pull off the drain cap on the
left side. (If you cannot pull it off by hand, use a long-
nose pliers.)
(d) Reattach the drain hose to the left side and the drain
cap to the right side. (Fig. 3-65)
Drain hose
Clamp
Drain cap
Fig. 3-65
17
Drain hose
Slide the drain hose fully onto the drain pan outlet until
the drain hose edge is pushed into the insulation. Check
that the screw holes in the drain bracket and the drain pan
outlet are aligned and securely in contact, then fasten them
with the screw. (After attaching the drain hose, check that it
is attached securely.) (Fig. 3-66)
Screw hole
Drain pan outlet
Insulation
Drain bracket
Drain bracket
Drain hose
Drain hose
Screw
Fig. 3-66
Drain cap
Use a Phillips screwdriver to push the drain cap in firmly.
(If it is difficult to push in, wet the cap with water first.)
(3) Install the indoor unit on the rear panel.
(4) Connect the tubing and wiring led inside from outdoors.
(5) After completing a leak test, bundle the tubing together
with armoring tape and store it inside the tubing storage
area at the back of the indoor unit and hold it with clamps.
(Fig. 3-67)
Refrigerant tubing
Inter-unit wiring
Fig. 3-67
To unmount indoor unit
Press the 2
marks on the lower part of the indoor unit and
unlatch the tabs. Then lift the indoor unit and unmount.
(Fig. 3-68)
Push
Fig. 3-68
3-19. Drain Hose
a)
The drain hose should be slanted downward to the
outdoors. (Fig. 3-69)
Slant
Indoor
Drain
unit
hose
Fig. 3-69
b)
Never allow a trap to form in the course of the hose.
c)
If the drain hose will run in the room, insulate the hose with
insulation* so that chilled condensation will not damage
furniture or floors. (Fig. 3-70)
Condensation
Insulation material
(locally purchased)
must be used.
Fig. 3-70
* Foamed polyethylene or its equivalent is recommended.
WARNING
Do not supply power to the unit or operate it until all tubing
and wiring to the outside unit are completed.
Risk of Electric Shock
18