• Insert the key in the lock.
• Turn the Front panel opening key counter-
clockwise.
• Open the Front panel.
IMPORTANT: Proceed with caution
• Extract the whole delivery unit including the
milk foamer, pulling it towards you.
• Extract the milk foamer from the delivery
group by sliding it upwards.
2
1
• Disconnect all the tubes attached to it.
• Disassemble the milk foamer and wash it
carefully.
NOTE:If the pause between one cappuccino
and another is over one hour long, it is
advisable to wash the milk foamer by
Fig. 47
fishing the milk suction tube in hot water
rather than in milk.
• To reassemble proceed inversely, attaching
the milk foamer tubes properly.
NOTE:To make the reassembling procedure
easier, an explanatory label has been
attached to the front door.
• Clean the drop collector (see paragraph
THE DROP COLLECTING TRAY GRID)
Fig. 48