Fig. 13 Device View of DSM-48DT
(listed as "DSM48-0774e3")

6.1.3 Routing with Dante Controller

To assign the input signals and output signals of the units involved:
1) In the window "Network View", tab "Routing", click the appro-
priate "+" buttons to open the channels of the Dante transmitter
desired and the channels of the DSM-48DT .
2) Starting at the Dante transmit channel, navigate to the row of the
desired Dante receive channel of the DSM-48DT and then click
the field .
3) Wait for the field to change to a green circle with a tick mark
(see figure below) .
4) Optionally, perform the previous two steps for the second Dante
receive channel of the DSM-48DT .
Fig. 14 Audio routing from the Dante unit "PM" to DSM-48DT
(in this example, designated as "DSM48-0774e3")
The Audinate website provides an English Dante Controller user guide
for download:
https://www .audinate .com/resources/technical-documentation

6.2 Selecting Dante as the signal source

6.2.1 Selecting Dante at the DSM-48DT

To select the Dante signals for the input channels IN3 and IN4:
1) Make sure that the inputs C and D are linked (
use the buttons CH to select
2) Use the buttons ITEM to select
3) Use the rotary knob to select
Note: The link of the two input signals can be disabled (Link Off) for individual
settings . The signal source, however, will remain the same for both channels .

6.2.2 Selecting Dante via the control program

To select the Dante signals for the input channels IN3 and IN4:
1) On the computer, call up the control program "DSP Controller"
(
 chapter 7) .
2) In the overview window (fig . 15) for the respective DSM-48DT, click
the button
to call up the configuration window with the view
MAIN (
 chapter 7 .3) .
3) In the view MAIN of the configuration window (fig . 17), select
the signal source "Dante" from the list field [7] located above the
controls of the channels IN3 and IN4 .
) and then
Link On
.
In CD
.
Source
.
Dante
31