16 - TROUBLESHOOTING TYPHOON

Error Codes
NOTE: Error codes appear on the In Service display.
Error Code
Error Type
---0
Motor Stall /Cam
Sense Error
---1
Motor Run-On Error
/Cycle Sense Error
---2
Regen Failure
---3
Memory Error
---4
Fail Safe Error
Cause
No state changes in the optical
sensor are detected for 6 seconds.
An undesired optical sensor state
change occured.
The system has not regenerated
for more than 99 days (or 7 days
if the Control Type has been set to
Day-of-Week).
Control board memory failure.
Valve has failed to find position in
one minute.
Reset and Recovery
Unplug the unit an plug back in. Allow the control to attempt to find
position again.
Verify the optical sensor is in place with the wires connected to the
circuit board. Verify the motor and drive train components are in good
condition and assembled properly. Check the valve and verify that the
piston travels freely. Replace/reassemble the various components as
necessary.
Plug the unit back in and observe its behavior. If the error reoccurs,
unplug the unit, put it into bypass and contact technical support.
Non-critical error. Extra optical sensor pulse detected. Press any
button to clear the error. Press extra cycle button to advance motor to
clear error.
Perform a Manual Regeneration to reset the error code.
If the system is metered, verify that it is measuring flow by running
service water and watching for the flow indicator on the display. If the
unit does not measure flow, verify that the meter cable is connected
properly and that the meter is functioning properly.
Enter Master Programming Mode and verify that the unit is configured
properly, For the valve configuration. Check that the correct system
capacity has been selected, that the day override is set properly, and
that meter is identified correctly. If the unit is configured as a Day-
of-Week system, verify that at least one day is set ON. Correct the
setting as necessary.
Perform a Master Reset and reconfigure the system via Master
Programming Mode. After reconfiguring the system, step the valve
through a manual regeneration. If error continues, call technical
support.
Unplug the unit and plug it back in. If error continues, call technical
support.
Fleck 5800 Storm & Typhoon Downflow/Upflow MR12 • 19