12 - MASTER PROGRAMMING MODE
TYPHOON
When the Master Programming Mode is entered, all available
option setting displays may be viewed and set as needed.
Depending on current option settings, some parameters cannot
be viewed or set.

Setting the Time of Day

1. Press and hold either the Up or Down buttons until the
programming icon replaces the service icon and the
parameter display reads TD.
2. Adjust the displayed time with the Up and Down buttons.
3. When the desired time is set, press the Extra Cycle button
to resume normal operation. The unit will also return to
normal operation after 5 seconds if no buttons are pressed.
Figure 13
Entering Master Programming Mode
Set the Time of Day display to 12:01 P. M. Press the Extra
Cycle button (to exit Setting Time of Day mode). Then
press and hold the Up and Down buttons together until the
programming icon replaces the service icon and the display
format screen appears.
Exiting Master Programming Mode
Press the Extra Cycle button to accept the displayed settings
and cycle to the next parameter. Press the Extra Cycle
button at the last parameter to save all settings and return to
normal operation. The control will automatically disregard any
programming changes and return to normal operation if it is
left in Master Programming mode for 5 minutes without any
keypad input.
Resets
Soft Reset
Press and hold the Extra Cycle and Down buttons for 25
seconds while in normal Service mode. This resets all
parameters to the system default values. Not reset are the
volume remaining in meter immediate or meter delayed
systems and days since regeneration in the time clock system.
Master Reset
Hold the Extra Cycle button while powering up the unit. This
resets all of the parameters in the unit. Check and verify the
choices selected in Master Programming Mode.
1. Display Format (Display Code DF)
This is the first screen that appears when entering Master
Programming Mode. The Display Format setting specifies
the unit of measure that will be used for volume and how
the control will display the Time of Day. This option setting is
identified by "DF" in the upper left hand corner of the screen.
There are two possible settings.
12 • MR12 Fleck 5800 Storm & Typhoon Downflow/Upflow
Display Format
Unit of Volume
Setting
GAL
U.S. Gallons
Ltr
Figure 14
2. Valve Type (Display Code VT)
Press the Extra Cycle button. Use the display to set the Valve
Type. 5800 is the only currently available valve type.
3. Regenerant Flow (Display Code RF)
Press the Extra Cycle button. The Regenerant Flow Setting
specifies the type of cycle that the valve follows during
regeneration. Note that some valve types require the valve
be built with specific subcomponents. Ensure the valve is
configured properly before changing the Valve Type setting.
This option setting is identified by "RF" in the upper left hand
corner of the screen. There are 8 possible settings.
Abbreviation
dF1b
Standard Downflow Single Backwash
dF2b
Standard Downflow Double Backwash
Fltr
AIO
dFFF
UFbd
UFFF
Othr
Figure 15
4. Control Type (Display Code CT)
Press the Extra Cycle button. Use this display to set the
Control Type. This specifies how the control determines when
to trigger a regeneration. For details on how the various
options function, refer to the "Timer Operation Typhoon"
section of this service manual. This option setting is identified
by "CT" in the upper left hand corner of the screen. There are
four possible settings.
Abbreviation
Fd
FI
tc
dAY
Time Display
12-Hour AM/PM
Liters
24-Hour
Parameter
Filter
Air Injection Oxidizer
Downflow Fill First
Upflow Brine First
Upflow Fill First
Other
Parameter
Meter (Flow) Delayed
Meter (Flow) Immediate
Time Clock
Day of Week