Herunterladen Inhalt Inhalt Diese Seite drucken

Inhaltsverzeichnis; Introduction; Contents; Manufacturer Identification Data - EBARA OPTIMA Serie Gebrauchs- Und Instandhaltungshandbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 14
INSTRUCTION MANUAL REGARDING USE AND MAINTENANCE
PART 1
To Be kePT By The user

1. INTRODUCTION

This instruction manual is made up of two parts: ParT 1 which con-
tains general information regarding all our production and ParT 2 which
contains specific information regarding the motor-driven pump that you
have purchased. The two booklets are complementary to each other,
therefore make sure that you have both of them.
Follow the instructions given in these booklets in order to obtain opti-
GB
mum return and operation from your motor-driven pump. If any other
information is necessary, please contact the nearest authorised retailer.
if the booklets contain contrasting information, keep to what is indicated
in ParT 2 (product specifications).
THE REPRODUCTION, EvEN PARTIAL, OF THE ILLUSTRATIONS
AND/OR TEXT HEREIN IS FORBIDDEN.
The following symbols are used throughout the instruction booklets:
WARNING!
Risk of damaging the pump or the system
Risk of injuring people or damaging things
Risks of an electrical nature

2. CONTENTS

7. INSTALLATION, DISMANTLING AND TRANSPORTATION page 7

3. MANUFACTURER IDENTIFICATION DATA

3.1. MANUFACTURER DATA
EBARA PUMPS EUROPE S.p.A.
Plant management:
via Pacinotti, 32 - 36040 Brendola (vi) iTaly
Telephone: 0444/706811 - Telefax: 0444/706950 - Telex: 480536
Registered office:
via campo sportivo, 30 - 38023 cles (Tn) iTaly
Telephone: 0463/660411 - Telefax: 0463/422782
3.2. MOTOR-DRIvEN PUMPS
See plates
in FIG. 6:
For product type, see PART 2.

4. GUARANTEE AND TECHNICAL ASSISTANCE

THE GUARANTEE IS RENDERED NULL AND vOID IF THE IN-
STRUCTIONS GIvEN IN THIS BOOKLET ARE NOT ADHERED
TO AND/OR IF ANYONE OTHER THAN PERSONNEL FROM OUR
HELP CENTRES INTERvENES ON THE MOTOR-DRIvEN PUMP. IN
THESE CASES, THE MANUFACTURER IS RELIEvED FROM ALL
6
6.1 for motor-driven surface pumps
6.2 for submersible motor-driven pumps
RESPONSIBILITY REGARDING INJURY TO PEOPLE AND SUB-
SEQUENT DAMAGE TO ADJACENT ITEMS AND/OR THE MOTOR-
DRIvEN PUMP ITSELF.
Once you have received the motor-driven pump, make sure that the
packaging is not broken or seriously damaged. If it is, immediately in-
form the person who delivered it. after extracting the motor pump from
its packaging, make sure that it was not damaged during transportation.
if it has been, inform the retailer within 8 days from delivery. check the
motor-driven pump plate to ensure that the indicated characteristics are
those requested by you.
The following parts, being normally subject to wear, have a limited guar-
antee:
• bearings
• mechanical seals
• grommets
• capacitors
If a fault that is not listed in the "TROUBLEShOOTING" table (chapter
10.1.) occurs, please contact the nearest authorised retailer.

5. GENERAL SAFETY WARNINGS

Before starting the motor-driven pump, the user must follow the opera-
tions indicated in this manual (PART 1 and PART 2), and apply them
each time the motor-driven pump is used or when maintenance is car-
ried out on it.
5.1. PREvENTIvE MEASURES TO BE TAKEN BY THE USER
Users must observe the accident prevention regula-
tions that are in force in their countries at the time.
They must also pay attention to the motor-driven
pump characteristics (see "TECHNICAL DATA" in
page 6
PART 2).
page 6
While repairing or carrying out maintenance on the
page 6
motor-driven pump, disconnect the electric supply.
page 6
Doing this avoids accidental starting, which could
page 6
injure people and/or cause damage.
page 7
Any maintenance, installation or handling carried out
on the motor-driven pump while it is still being pow-
page 7
ered can seriously injure, or even kill, people.
page 8
page 8
When starting the motor-driven pump, users must en-
page 9
sure that their feet are not bare or, worse, immersed
page 9
in water. They must also ensure that their hands are
not wet.
page 73
Users must not operate or carry out any work on
the motor-driven pump that is not permitted in this
manual.
5.2. IMPORTANT PROTECTIONS AND CAUTIONS
All motor-driven pumps are designed in such a way
that all moving parts are made safe by using guards.
The manufacturer declines any responsibility in the
event of damages caused by the removal of said pro-
tections.
Each conductor or powered part is electrically insula-
ted with regards to earth. Extra security is also added
by connecting the accessible conducting parts to an
earth conductor. This ensures that accessible parts
cannot become dangerous should the main insula-
tion become faulty.
5.3. RESIDUAL RISKS FOR SURFACE PUMPS
The only residual risk is the possibility of coming into contact (even if
not accidentally) with the motor cooling fan by inserting thin objects (i.e.
screwdrivers, small sticks, etc.) through the holes of the fan cover.