17. Technical data

Input voltage/current ....................... 2 x 1.5 V/DC LR6 batteries (included)
Battery life .......................................Approx. 5 hours (continuous operation)
Minimum length for tests ................>5 m (data cable and coaxial cable)
Maximum length for tests ............... 3 .0 km @ V.O.P ≤99.9 %
Range .............................................Automatic length control
Resolution .......................................0.1 m
Accuracy ......................................... (±2 % of the measured value ±0.2 m) <100 m
Impedance selection .......................Automatic output impedance selection
Speed factor ...................................Adjustable from 1 % to 99.9 %
Connections (test cable) .................BNC, RJ45
Cable types .....................................20 standard types of cable pre-set
Memory locations ...........................99
LC display .......................................2.4"
Operating conditions ....................... 0 to +40 °C,
Storage conditions .......................... -10 to +50 °C,
Dimensions (L x W x H) .................152 x 61 x 34 mm
Weight ............................................230 g
2.4 km @ V.O.P ≤80.0 %
2.0 km @ V.O.P ≤66.0 %
1.5 km @ V.O.P ≤50.0 %
(±2 % of the measured value ±0.5 m) ≥100 m
<80 % relative humidity (non-condensing)
>80 % relative humidity (non-condensing)