Error Possible cause
The device
does not work.
None Change of the
measuring value.
Repairs other than those described should only be carried out by an authorised spe-
cialist. If you have queries about handling the measuring device, our technical sup-
port is available under the following telephone number:
Voltcraft®, 92242 Hirschau, Lindenweg 15, phone 0180 / 586 582 7
TECHNICAL DATA
Display
Measuring cable length
Measuring impedance
Automatic switch-off
Operating voltage
Working conditions
Operating altitude
Storage temperature
Weight
Dimensions (LxWxH)
Over-voltage category
Cable detector
Signal
Status indicator
continuity tester
Measuring cable length
Overload protection
38
Remedy
Is the battery dead?
Is a wrong measuring function
activated (AC/DC)?
Is the HOLD function activated?
(display "HOLD").
LCD; 2000 counts
about 80 cm each
>7.5 MΩ (V range)
approx. 15 minutes
DMM
Signaller
Receiver
0 to 40°C (<75%rh)
max. 2,000 m
-10°C to +50°C (<80%rh)
DMM
Receiver
DMM
Receiver
CAT III 600 V, contamination degree 2
(only DMM via safety sockets)
Permanent sound ca. 800 – 860 Hz; wobble sound ca. 800 – 1050 Hz
max. 50 V
<10 kΩ (optical)
Banana clips approx. 50 cm each, modular plug ca. 25 cm
<75 V/DC, <50 V/AC
Check the status.
Battery replacement
Check the display (AC/DC)
and switch the function if applicable.
Press the button "HOLD" to
deactivate this function.
2 x micro batteries (AAA)
9V block battery
9V block battery
ca. 308 g
ca. 125 g
162 x 74 x 44 (mm)