Chimney

The smoke flue is only installable on top of the stove. The stove's flue pipe has no rear outlet.
The chimney is the driving force which makes the stove function. Keep in mind that even the
best
stoves would not function well without necessary and proper draught in the chimney.
The chimney height must be sufficient to ensure the correct draught of 14 to 18 Pa. If the chim-
ney draught is lower than recommended, there may be problems problems of smoke leaking
into the room when the stove is lit. RAIS
recommends to adjust the chimney height with the flue pipe collar. The chimney should be at
least
3 metres long from the top of the stove, and be at least 80 cm above the roof
ridge. For chimneys placed along the house sides, the chimney tops should always rise
above the roof ridge's highest point.
Note that national and local regulations on houses often have provisions for thatched roofs.
You should also familiarise yourself with the draught conditions for chimneys with 2 flues.
The stove is suitable for connection with the flue gas collector, however, we recommend to
place inlets to ensure a minimum ground clearance between them to be at least 250 mm.
The flue outlet socket should be 150 mm in diameter.
For strong draughts, the chimney should be fitted with a draught damper. In which case, it is
important to ensure that there is a free flow -through area of minimum 20 cm² when the regu-
lating damper is shut. Otherwise, the fuel energy may not be used optimally. If you are unsure
about the condition of the chimney, you should contact a chimney sweep.
Remember that access to the soot door should be kept clear.
Ensure the access for cleaning the fireplace, flue collar and flue pipe.
Note: The stove may be installed only by a qualified/
competent RAIS dealer/installer.
See www.rais.com for dealer list.